中国激光, 2001, 28 (5): 407, 网络出版: 2006-08-10
超强脉冲激光系统光束质量的测量和改善
Beam Quality Measurement and Amendment of the Ultrashort Ultraintense Laser System
摘要
总结了类高斯分布光束的M2因子在实验测量中的数据处理方法,介绍在5.4TW/46fs激光系统中测量M2的实验设置以及改善该系统光束质量的措施,报道了测量结果并分析了该装置的性能。
Abstract
This paper summarizedthe method of M2 factor measuring and data processing for quasi-gaussdistribution beams and measured the M2 factor of the 5.4 TW/46 fs laser system.The experiment setup and the steps of amending the beam quality are briefly introduced.The result was reported with some analysis about the performance of this system.
胡雪原, 邓健, 钟方川, 杨晓东, 王文跃, 张正泉, 李儒新, 徐至展. 超强脉冲激光系统光束质量的测量和改善[J]. 中国激光, 2001, 28(5): 407. 胡雪原, 邓健, 钟方川, 杨晓东, 王文跃, 张正泉, 李儒新, 徐至展. Beam Quality Measurement and Amendment of the Ultrashort Ultraintense Laser System[J]. Chinese Journal of Lasers, 2001, 28(5): 407.