强激光与粒子束, 2003, 15 (1): 101, 网络出版: 2006-04-28   

Z-pinch X射线时间分辨多幅图像诊断系统

Time resolved X-ray image diagnostic system for Z-pinch
作者单位
1 西北核技术研究所,陕西西安,710024
2 西北核技术研究所,陕西西安,710
摘要
介绍了为"强光一号"设计的ns级时间分辨软X射线多幅图像诊断系统,分析了系统的主要性能指标,给出并分析了利用该系统诊断"强光一号"高功率脉冲Z-pinch等离子体辐射源的最新的实验结果.
Abstract
A high speed gated soft Xray multiframe image diagnostic system was developed for QiangGuangI generator, which was operated with a peak current of 1.5MA and a rise time of 80ns. In the system, a gated fourframe (3~5ns gate, 5~20ns separation) Xray camera, used in conjunction with a set of filtered pinholes was employed. Pinholes of 0.1mm and 0.3mm were used, which gave a spatial resolution of 0.56mm and 1mm, respectively. The pinholes were filtered with 2μm aluminized mylar. The system was sensitive to 150~300eV photons and to those greater than 550eV. Finally the last experimental results measured by this system in QiangGuangI generator were discussed.

邱孟通, 吕敏, 王奎禄, 黑东炜, 邱爱慈, 曾正中, 杜继业, 蒯斌, 袁媛, 田慧, 孙凤荣, 罗建辉. Z-pinch X射线时间分辨多幅图像诊断系统[J]. 强激光与粒子束, 2003, 15(1): 101. 邱孟通, 吕敏, 王奎禄, 黑东炜, 邱爱慈, 曾正中, 杜继业, 蒯斌, 袁媛, 田慧, 孙凤荣, 罗建辉. Time resolved X-ray image diagnostic system for Z-pinch[J]. High Power Laser and Particle Beams, 2003, 15(1): 101.