光子学报, 2006, 35 (4): 0587, 网络出版: 2010-06-03   

共聚焦成像系统中探测器对分辨率的影响

Influence of Detector on Resolution in Confocal Imaging System
作者单位
1 东华大学信息科学与技术学院,上海 200051
2 上海大学通信与信息工程学院,上海 200072
3 上海交通大学激光与光子生物研究所,上海 200030
摘要
基于点扩展函数,推导出共焦系统的成像公式,模拟了探测器尺寸对分辨率的影响,并提出最佳针孔半径.为验证理论分析,设计并建立了一套共焦系统,测量了不同针孔时的轴向响应,并得到了鉴别率板的共焦和离焦像.
Abstract
The imaging equations are derived based on point spread function,the influence of detector on resolution is simulated,and the optimum pinhole radius is proposed. To demonstrate the theoretical calculation,the confocal imaging system is designed and established. The axial response is measured for different pinhole,and the in-focus and out-of-focus images of bar target are obtained with the confocal system.

葛华勇, 王保华, 任秋实. 共聚焦成像系统中探测器对分辨率的影响[J]. 光子学报, 2006, 35(4): 0587. Ge Huayong, Wang Baohua, Ren Qiushi. Influence of Detector on Resolution in Confocal Imaging System[J]. ACTA PHOTONICA SINICA, 2006, 35(4): 0587.

本文已被 5 篇论文引用