光学学报, 1994, 14 (12): 1316, 网络出版: 2007-08-17  

X射线胶片的脉冲光源响应标定

Response Calibration of X-Ray Film to a Pulse X-Ray Source
作者单位
西南核物理与化学研究所, 成都 610003
摘要
用LF-11激光装置的1.06 μm脉冲激光加热Cu靶产生的L-壳层线辐射作脉冲X射线源,在曝光量为(0.01~10)-7 J·cm-2范围内,标定了KODAK AA-5,KODAk SWR和UFSH-O软X射线胶片的响应曲线,并与用连续光源标定的进行了对比.结果表明,这三种x射线胶片,在强脉冲光源曝光条件下,都存在着胶片响应互易律失效问题,过去用连续光源标定的响应曲线,在激光等离子体诊断实验中,已经不能采用.
Abstract
By using the strong L-lines emitted from Cu plasma as pulse X-ray source produced by irradiating Cu target with a 1.06 μm pulse laser of the LF-11 laser facility,the reponses of X-ray film Kodak AA-5, Kodak SWR and UFSH-O were calibrated.Calibrated responses with the pulse X-ray source were compared with that with continuum X-ray source (fluoresent source exciteed by protons). These results showed the reciprocity failure. The response to continuum X-ray source is not suitable for the diagnostics in laser-induced plasma.

何绍堂, 黄文忠, 孙永良, 易荣清, 周裕清, 何安, 杜凤英, 洪伟. X射线胶片的脉冲光源响应标定[J]. 光学学报, 1994, 14(12): 1316. 何绍堂, 黄文忠, 孙永良, 易荣清, 周裕清, 何安, 杜凤英, 洪伟. Response Calibration of X-Ray Film to a Pulse X-Ray Source[J]. Acta Optica Sinica, 1994, 14(12): 1316.