光学学报, 2008, 28 (4): 710, 网络出版: 2008-04-21   

光谱仪联合使用提高谱线的测量宽度

Spectral Linewidth Measurement Enhancement by Two United Spectrometers
作者单位
1 西安工程大学理学院, 陕西 西安 710048
2 西安理工大学理学院, 陕西 西安 710048
摘要
为了提高光谱仪测量谱线的精度,推导出计算机自动控制多光栅转动的光谱仪测试系统的角色散率、线色散率和分辨本领等参量公式,提出一种将两台光谱仪联合使用以提高谱线测量精度的测量方法。理论分析了两台光谱仪联合测激光线宽的原理,并用两台光谱仪联合使用对He-Ne激光谱线宽度进行了测量。实验结果表明,两台光谱仪联合测量He-Ne激光谱线的半峰全宽的放大倍数3.38×105,比单台光谱仪测量至少可以将谱线宽度的测量精度提高5个数量级。
Abstract
In order to improve the measuring precision of spectral line by spectrometer, the parameters of angle dispersive power, line dispersive power and resolving power of spectrometer with grating scanning controlled by computer have been calculated theoretically, and then a method has been put forward to improve the linewidth measurement by two united homogeneous spectrometers. The principle of measuring laser linewidth by two united spectrometers is analyzed theoretically, and the linewidth of He-Ne laser is measured. The experimental results shows amplification factor of full width at half maximum (FWHM) of He-Ne laser spectral line is 3.38×105, and 5 order magnitude of the line width measurement is enhanced at least by the two united homogeneous spectrometers than only one.

刘汉臣, 王庆飞, 唐远河, 严祥安. 光谱仪联合使用提高谱线的测量宽度[J]. 光学学报, 2008, 28(4): 710. Liu Hanchen, Wang Qingfei, Tang Yuanhe, Yan Xiangan. Spectral Linewidth Measurement Enhancement by Two United Spectrometers[J]. Acta Optica Sinica, 2008, 28(4): 710.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!