强激光与粒子束, 2009, 21 (2): 291, 网络出版: 2009-11-24  

中子闪烁探测器前端电子学的抗饱和改进

Anti-saturation improvement of front-end electronics for neutron detectors array system
作者单位
中国科学技术大学 安徽省物理电子学重点实验室,合肥 230026
摘要
ICF实验会产生大量X射线和γ射线,其在光电倍增管(PMT)中产生的脉冲信号过大,导致前端电子学电路饱和,严重影响电路的正常工作和中子飞行时间的测量。结合前端电子学系统的结构,对电路饱和的原因进行了深入分析,提出了非线性抗饱和电路改进方案,并进行了仿真和实验研究。仿真结果表明,该设计方案能够大幅衰减大信号而确保小信号的通过,信号通过后电路基线能在35 ns内恢复;电路的实测结果与仿真结果基本相同。这表明:采取的方案简洁有效,能够确保输入高达数十V脉冲的情况下电路的正常工作。目前这一电路已经得到应用,并将安装在某大型激光原型的大阵列中子探测器上。
Abstract
The too strong pulse from a photomultiplier tube,produced by X-rays and gamma rays generated in the ICF experiment,leads to the saturation of the front-end electronics.It impedes normal circuit operation and measurement of the flight time of neutrons.An improved anti-saturation nonlinear circuit has been put forward and tested on the basis of the front-end electronics structure and further analysis of its saturation.Simulation results indicate that the improved circuit could introduce great attenuations for large amplitude pulses and pass through small amplitude pulses.The baseline of the circuit can recover within 35 ns. The experimental test has got the same results as the simulation does. It shows that the improved solution is simple and effective,and it could ensure the normal circuit operation for input pulses with dozens of volts. Now the circuit has been applied to the front-end electronics and will be installed on the large neutron detector array of certain large laser prototype soon.

李锋, 江晓, 林成生, 陈炼, 梁福田, 金革. 中子闪烁探测器前端电子学的抗饱和改进[J]. 强激光与粒子束, 2009, 21(2): 291. Li Feng, Jiang Xiao, Lin Chengsheng, Chen Lian, Liang Futian, Jin Ge. Anti-saturation improvement of front-end electronics for neutron detectors array system[J]. High Power Laser and Particle Beams, 2009, 21(2): 291.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!