摘要
通过分析光学元件的动力学响应,计算靶场每条光路的结构漂移误差,进行了靶场结构总体稳定性评估。神光主机装置单光路靶场结构漂移误差计算结果表明:其靶场结构设计满足稳定性要求,该方法可以应用在ICF装置靶场结构总体稳定性设计中,但所得的漂移误差的裕度应大于一个给定的合理值。
Abstract
In order to meet the stringent stability requirement,target area structural systemic stability design was used in the inertial confinement facilities in which National Ignition Facility(NIF)of USA and SG facility are representative.In the structural systemic stability design of the SG facility target area,a new analytical method was proposed to obtain the drifting error of each beam by accounting the dynamic responses of the optical elements.This stability evalutation method was different from that of National Ignition Facility of USA.The calculated drifting errors of the beams indicate that the designed structural system has meet the stability requirement of the SG facility target area.It is concluded that this analytical method can be used in the structural systemic stability design of the inertial confinement facility target area,but the abundance of the obtained drifting error of each beam must be beyond a reasonable given value.

徐元利, 吴文凯, 陈学前, 陈晓娟. ICF装置靶场结构总体稳定性设计[J]. 强激光与粒子束, 2009, 21(10): 1485. Xu Yuanli, Wu Wenkai, Chen Xueqian, Chen Xiaojuan. Structural systemic stability design of inertial confinement fusion facility target area[J]. High Power Laser and Particle Beams, 2009, 21(10): 1485.

本文已被 7 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!