光学与光电技术, 2009, 7 (2): 86, 网络出版: 2009-12-30   

正支共焦非稳腔的自动准直调整实验研究

Experiment Study on the Auto-Alignment of a Positive-Branch Confocal Unstable Resonator
作者单位
国防科学技术大学光电科学与工程学院, 湖南 长沙 410073
摘要
谐振腔的自动准直调整技术是实现高能激光器系统自动化的关键技术之一。在对正支共焦非稳腔自动准直调整方法的研究基础上,应用基于系统性能评价函数无模型最优化的随机并行梯度下降(SPGD)控制算法实现腔的自动准直调整。实验结果表明该方法可实现腔镜的闭环控制准直调整, 其调腔共轴精度在一定程度上高于传统的人工调腔精度。
Abstract
The automatic alignment of the resonators is one of the critical techniques in realizing high-power laser automatic system. In this paper, by studying the methods of auto-alignment of the confocal unstable resonators, the stochastic parallel gradient descent (SPGD) optimization algorithm based on model-free optimization of the system performance metric is applied to realize auto-alignment of the resonator. The experiment results show that this method can implement closed loop control alignment of the mirrors of the resonator, and it improves the alignment precision of the resonator in a certain extent. The work of this paper provides a technical reference for a practicability high-power laser automatic system.

尹新华, 梁永辉, 谢文科, 于起峰. 正支共焦非稳腔的自动准直调整实验研究[J]. 光学与光电技术, 2009, 7(2): 86. YIN Xin-hua, LIANG Yong-hui, XIE Wen-ke, YU Qi-feng. Experiment Study on the Auto-Alignment of a Positive-Branch Confocal Unstable Resonator[J]. OPTICS & OPTOELECTRONIC TECHNOLOGY, 2009, 7(2): 86.

本文已被 2 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!