红外, 2009, 30 (8): 18, 网络出版: 2010-05-26   

基于作用距离的红外成像系统光学参数确定

Calculation of Optical Parameters of Infrared Imaging System Based on Operating Distance
作者单位
1 大连工业大学光子学研究所,辽宁大连116034
2 大连东软信息学院嵌入式系统工程系,辽宁大连116023
摘要
作用距离是决定红外成像系统性能的重要指标,可直接影响红外成像光学系统的参数确定。基于作用距离的参数确定方法建立了探测器与作用距离、空间分辨率之间的关系,对光学系统的参数确定和性能评价具有重要作用。结合实例确定了红外成像系统光学的主要参数,采用非制冷凝视型长波红外探测器(工作波段为8μm rv 12μm) ,在特定的作用距离下,利用该方法确定的红外光学系统通光口径为90mm , F 数值为1 0
Abstract
Operating distance is one of the important specifications of an infrared imaging system. It can affect the determination of the parameters for an infrared imaging optical system. Because the parameter determination method based on operating distance has established the relations among a detector, the operating distance and the spacial resolution, it is of importance to the parameter determination and performance evaluation of an optical system. In this paper, the main parameters of a practical infrared imaging system with an uncooled staring long wavelength infrared detector operating in the waveband of 8μm rv 12μm are determined. At a particular operating distance, the clear aperture and F number of the infrared optical system are measured to be 90mm and 1 respectively by using this method.

张云翠, 刘龙, 杨轶, 曹冠英, 张竞辉, 邹念育. 基于作用距离的红外成像系统光学参数确定[J]. 红外, 2009, 30(8): 18. ZHANG Yun-cui, LlU Long, YANG Yi, CAO Guan-Ying, ZHANG Jing-hui, ZOU Nian-Yu. Calculation of Optical Parameters of Infrared Imaging System Based on Operating Distance[J]. INFRARED, 2009, 30(8): 18.

本文已被 2 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!