大气与环境光学学报, 2009, 4 (5): 341, 网络出版: 2010-05-26
奥运期间北京某工业区排放通量的车载被动DOAS遥测研究
Remote Sensing of the Emission Flux from an Industrial Area by Mobile Passive DOAS During Beijing Olympic Games
被动差分吸收光谱法 北京奥运会 区域污染源 排放通量 passive differential optical absorption spectrosco Beijing Olympic Games area source flux
摘要
利用车载被动差分吸收光谱遥测技术,对奥运期间北京市某大型钢铁厂所在区域内的SO2和NO2排放 通量进行了测量。观测结果表明奥运会赛时该区域SO2和NO2排放通量的平均值分别为4.1 ton/h和1.0 ton/h,并 通过对比表明车载被动DOAS与其它仪器测量结果有较好的一致性。进一步分析后给出了相比6月份两种污染气 体排放通量下降了约44%和78%的结果,说明了减排措施的显著效果。
Abstract
Mobile passive differential optical absorption spectroscopy (DOAS) was used for the remote sensing of the emission flux of SO2 and NO2from area of a steel company during Beijing Olympic Games. The mean values of SO2and NO2flux were 4.1 ton/h and 1.0 ton/h derived from the observation results. The comparison of mobile passive DOAS results with MAX-DOAS observations shows a preferable identity and suggests that the results are reasonable and reliable. A further analysis revealed that the emission flux of these two gaseous pollutants decreased about 44% and 78% respectively. These results indicated that emission reduction had a remarkable effect.
李昂, 谢品华, 窦科, 刘宇, 刘文清, 刘建国. 奥运期间北京某工业区排放通量的车载被动DOAS遥测研究[J]. 大气与环境光学学报, 2009, 4(5): 341. LI Ang, XIE Pin-hua, DOU Ke, LIU Yu, LIU Wen-qing, LIU Jian-guo. Remote Sensing of the Emission Flux from an Industrial Area by Mobile Passive DOAS During Beijing Olympic Games[J]. Journal of Atmospheric and Environmental Optics, 2009, 4(5): 341.