中国激光, 2010, 37 (6): 1421, 网络出版: 2010-07-07   

基于空心光纤构建微管生物传感器的实验研究

Experimental Research on Micro-Tube Biosensor Based on Hollow Optical Fiber
作者单位
天津大学精密仪器与光电子工程学院光电信息技术科学教育部重点实验室, 天津 300072
摘要
基于空心光纤构建微管生物传感器,进行了空心光纤的回音壁谐振模(WGM)理论分析,阐述了基于折射率变化检测的微管生物传感器工作原理。采用ZF13棱镜通过倏逝场耦合成功激发了微管的回音壁谐振模。利用不同浓度的乙醇水溶液初步展示了微管生物传感器回音壁谐振模谐振波长对折射率的敏感性,在1555.0 nm谐振波长处,当入射光角度为45°时,获得2.2 nm/RIU(RIU为折射率单元)的传感灵敏度,在入射光角度为36°时,获得21.2 nm/RIU的传感灵敏度。
Abstract
Micro-tube biosensor is established with hollow optical fiber and its whispering gallery mode (WGM) is analyzed theoretically. The principle of bio-sensing based on the change of refractive index is presented. With the prism of ZF13, WGM of micro-tube is successfully observed by evanescent coupling. The mixture of water and ethanol is used for experimental research on sensitivity with the change of refractive index of micro-tube biosensor. At the resonance wavelength of 1555.0 nm, 2.2 nm/RIU sensitivity is obtained with 45° incident angle and 21.2 nm/RIU is obtained with 36° incident angle.

江俊峰, 李海伟, 刘铁根, 刘琨, 张以谟. 基于空心光纤构建微管生物传感器的实验研究[J]. 中国激光, 2010, 37(6): 1421. Jiang Junfeng, Li Haiwei, Liu Tiegen, Liu Kun, Zhang Yimo. Experimental Research on Micro-Tube Biosensor Based on Hollow Optical Fiber[J]. Chinese Journal of Lasers, 2010, 37(6): 1421.

本文已被 4 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!