光谱学与光谱分析, 2010, 30 (2): 340, 网络出版: 2010-07-23  

用近红外无损肌氧及运动心率检测技术评定100 m极量强度运动对心脏冲击影响

Evaluation of Heart Impact in the 100 m Extreme Intensity Sport Using Near-Infrared Non-Invasive Muscle Oxygen Detecting Device and Sports Heart Rate Detection Technology
作者单位
1 清华大学医学院, 北京 100084
2 新乡医学院, 河南 新乡 453003
3 华中科技大学生物系, 湖北 武汉 430074
4 湛江师范学院, 广东 湛江 524048
摘要
利用连续双波长近红外光技术测量肌肉中血红蛋白含氧量的变化情况, 同时应用运动心率无线实时采集设备, 设计了检测实时肌肉组织血氧含量和瞬时心率实验方案, 对6名健康男性进行了100 m跑同步实测实验。 实验表明, 肌肉组织氧合血红蛋白浓度在100 m跑结束后继续降低, 达到最低值的时刻滞后于运动结束时刻的时间为(6.65±1.10)s; 心率则在运动结束后继续上升, 达到最高值的时刻滞后于运动结束时刻的时间为(8.00±1.57)s。 这些结果显示了双波长近红外光组织氧测试技术和运动心率无线实时采集系统能够正确检测极量强度运动时的血氧参数和心率, 揭示了极量强度运动过程中肌肉中氧运输与消耗的过程及其与心率之间的动力学特征。
Abstract
Using continuous two wavelength near-infrared technology to detect the variation in the consistency of oxygen hemoglobin in the muscle and the sports heart rate wireless real time collection technology, we devised the real time muscle tissue oxygenation and instantaneous heart rate experiment scheme and implemented it for the process of the 100 m run with two parameters given simultaneously. The experiment shows that the concentration of the oxygen hemoglobin in the muscle tissue continues decreasing after the end of the 100 m run, and the time interval between the moment when the concentration of the oxygen hemoglobin attains the minimum value and the moment when the athletes finish the 100 m run is (6.65±1.10) sec; while the heart rate continues increasing after the end of the 100 m run, and the time interval between the moment when the heart rate attains the maximum value and the moment when the athletes finish the 100 m run is (8.00±1.57) sec. The results show that the two wavelength near-infrared tissue oxygenation detection technology and the sports heart rate real time collection equipment can accurately measure the sports tissue oxygenation and the heart rate in the extreme intensity sport, and reveal the process of muscle oxygen transportation and consumption and its dynamic character with the heart rate in the extreme intensity sport.

王培勇, 龙非筱, 傅兰英, 李岳, 丁海曙, 瞿安连, 周小平, 腾轶超, 邢瑜, 杨良策. 用近红外无损肌氧及运动心率检测技术评定100 m极量强度运动对心脏冲击影响[J]. 光谱学与光谱分析, 2010, 30(2): 340. WANG Pei-yong, LONG Fei-xiao, FU Lan-ying, LI Yue, DING Hai-shu, QU An-lian, ZHOU Xiao-ping, TENG Yi-chao, XING Yu, YANG Liang-ce. Evaluation of Heart Impact in the 100 m Extreme Intensity Sport Using Near-Infrared Non-Invasive Muscle Oxygen Detecting Device and Sports Heart Rate Detection Technology[J]. Spectroscopy and Spectral Analysis, 2010, 30(2): 340.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!