应用光学, 2010, 31 (3): 400, 网络出版: 2010-08-03  

交变磁场对电子罗盘姿态输出精度影响的定量分析

Alternating magnetic field effect on 3 axes compass module
作者单位
1 92941部队94分队, 辽宁 葫芦岛 125001
2 海军驻20所军代室, 陕西 西安 710065
3 西安应用光学研究所, 陕西 西安 710065
摘要
在理想电磁环境中对姿态测量元件电子罗盘进行了校准, 给出了校准所需的标准参数设置。分别对电子罗盘在理想电磁环境与单交变磁场环境中以及二重及三重交变叠加磁场环境下的姿态角输出进行了对比分析, 实时测量了两种典型状态下罗盘局部交变干扰磁场强度并绘出二维交变图。结果显示:随着交变干扰磁场强度的增大, 3个姿态角输出精度均呈降低趋势。尤其是航向角最为严重, 这与其特殊的敏感原理吻合。文末给出了精度变化的电磁数据原因。提出了避免罗盘精度降低的方法。
Abstract
A 3 axes compass module is calibrated in ideal magnetic environment, and standard calibration parameters are put forward. The output of compass module is measured and compared in ideal magnetic environments of single, two and three alternating magnetic fields. Real-time alternating magnetic density about compass module in two representative states was measured and the result was given. The result shows that the precision of compass module decreases with the increase of the magnetic density, especially at heading direction, which agrees with specific sensitivity theory of compass. The reason of this phenomenon is given and the method of improvement is suggested.

张威, 汤卫红, 郝利锋, 梁晓东, 江涛. 交变磁场对电子罗盘姿态输出精度影响的定量分析[J]. 应用光学, 2010, 31(3): 400. ZHANG Wei, TANG Wei-hong, HAO Li-feng, LIANG Xiao-dong, JIANG Tao. Alternating magnetic field effect on 3 axes compass module[J]. Journal of Applied Optics, 2010, 31(3): 400.