为了满足环境污染检测等工业实际应用的需要,便于系统的集成、降低成本,研制了基于CCD芯片的 微型光谱仪,重点介绍了仪器的光学和电子学设计。 光学系统采用了非对称交叉式Czerny-Turner分光结构,使用线阵CCD为光探测元件;电子学设计 部分结合单片机智能化控制的特点和复杂可编程逻辑器件时序准确、 可编程的优点实现了高效、灵活的光谱数据采集。CCD光谱仪的性能测试表明,该光谱仪光谱覆盖 范围为350780 nm,光谱分辨率达到了0.6 nm,信噪比近500。

Abstract

In order to meet the practical industry application requirement of environmental pollution test and facilitate the integration of system and reduce the cost, a micro-spectrometer based on linear CCD array is developed. The design of optical and electronics is introduced. A Czerny-Turner optical structure and linear CCD as light detection device are used in the system. In the electronics design, an efficient and flexible data acquisition is achieved by combining intelligent control of microcontroller and accurate timing, programmable of complex programmable logic device. The performance test of micro spectrometer shows that its spectral coverage is between 350 nm and 780 nm, its spectral resolution comes to 0.6 nm and the signal to noise ratio is close to 500.

广告组1 - 空间光调制器+DMD
补充资料

中图分类号:TP274

DOI:10.3969/j.issn.1673-6141.2011.04.009

所属栏目:光电技术

基金项目:国家高技术研究发展计划项目(2009AA06Z204)、中国科学院重大科研装备研制项目(YZ200818)资助

收稿日期:2011-02-17

修改稿日期:2011-03-11

网络出版日期:--

作者单位    点击查看

王伟兰:中国科学院安徽光学精密机械研究所环境光谱学研究室, 安徽 合肥 230031
谈图:中国科学院安徽光学精密机械研究所环境光谱学研究室, 安徽 合肥 230031
汪磊:中国科学院安徽光学精密机械研究所环境光谱学研究室, 安徽 合肥 230031
高晓明:中国科学院安徽光学精密机械研究所环境光谱学研究室, 安徽 合肥 230031

联系人作者:王伟兰(wangweilan1984@163.com)

备注:王伟兰(1984-)女,江苏盐城人,研究生,主要研究方向是气体光学传感技术和光电子信号检测技术。

【1】Ju Hui, Wu Yihui. Miniature spectrometer development [J]. Journal of Micro-Nano Electronic Technology, 2003, (1): 30-37(in Chinese).
鞠辉, 吴一辉. 微型光谱仪的发展 [J]. 微纳电子技术, 2003, (1): 30-37.

【2】Wang Qingyou. The Applications of CCD [M]. Beijing: Electronic Industry Press, 2003: 111-114(in Chinese).
王庆有. 图像传感器应用技术 [M]. 北京: 电子工业出版社, 2003: 111-114.

【3】TCD1304AP Datasheet [Z/OL]. http://www.eure ca.de/pdf/optoelectronic/toshiba/TCD1304AP.pdf.

【4】Peng Xiaojun, He Ping’an, Yuan Bingxia. Design and implementation of a new linear CCD driver based on CPLD [J]. Journal of Optoelectronics Laser, 2007, 18(7): 803-807(in Chinese).
彭晓钧, 何平安, 袁炳夏. 基于CPLD的线阵CCD驱动电路设计与实现 [J]. 光电子激光, 2007, 18(7): 803-807.

【5】Xia Ruobin. Data Acquisition and Digital Signal Processing of CCD Spectrometer [D]. Hangzhou: Master’s Thesis of Zhejiang University, 2006: 46-55(in Chinese).
夏若彬. CCD光谱测量系统的数据采集及数字化处理 [D]. 杭州: 浙江大学硕士论文, 2006: 46-55.

【6】Ding Lei. Design of data acquisition system for spectrum measurement based on CPLD and CCD [J]. Journal of Atmospheric and Environmental Optics, 2010, 5(6): 469-474(in Chinese).
丁蕾. 基于CPLD与CCD光谱测量数据采集系统设计 [J]. 大气与环境光学学报, 2010, 5(6): 469-474.

【7】Shen Jianhua, Yang Yanqin. Principle and Realization of MSP430 16 Ultra-Low Power Single-Chip Microcomputer [M]. Beijing: Beihang University Press, 2008: 152-160(in Chinese).
沈建华, 杨艳琴. MSP430系列16位超低功耗单片机原理与实现 [M]. 北京: 北京航空航天大学出版社, 2008: 152-160.

引用该论文

WANG Wei-lan,TAN Tu,WANG Lei,GAO Xiao-ming. Development of Micro-Spectrometer Based on Linear CCD Chip[J]. Journal of Atmospheric and Environmental Optics, 2011, 6(4): 299-304

王伟兰,谈图,汪磊,高晓明. 基于线阵CCD的微型光谱仪的研制[J]. 大气与环境光学学报, 2011, 6(4): 299-304

被引情况

【1】胡开付,王双保. 基于FPGA的CCD光积分时间大范围实时自调节系统. 大气与环境光学学报, 2012, 7(5): 376-384

【2】夏果,黄禅,吴骕,金施群,邢金玉. 微型光谱仪增益及读出噪声的测量方法. 光学学报, 2017, 37(1): 112001--1

【3】高明,许黄蓉. 低成本光谱仪的研制. 光学仪器, 2017, 39(2): 77-80

您的浏览器不支持PDF插件,请使用最新的(Chrome/Fire Fox等)浏览器.或者您还可以点击此处下载该论文PDF