大气与环境光学学报, 2011, 6 (5): 351, 网络出版: 2011-09-27   

广州亚运会期间多组分污染气体的抽取式FTIR监测

Polluted Multi-Gas Monitoring by Extraction FTIR During Guangzhou Asian Games
作者单位
中国科学院安徽光学精密机械研究所中国科学院环境光学与技术重点实验室, 安徽 合肥 230031
摘要
利用抽取式傅里叶变换红外光谱(FTIR)测量系统于2010广州亚运会期间对广州白云机场地区大气中的 多种污染气体进行了连续监测。介绍了系统组成和光谱定量分析方法,并对浓度结果进行了分析。结果显 示,一氧化碳和臭氧小时均值浓度具有日周期变化,虽然在监测期间出现了几个极值,但是仍然达到国家二 级标准。乙烯和乙炔小时均值浓度具有同步变化规律,两者应来自同一排放源。在整个亚运会期间所监 测的污染物组分中未发生明显超标状况,在此期间采取的减排控制措施是有效的。
Abstract
The polluted multigases in the atmosphere were continuously monitored around Guangzhou Baiyun Airport with extraction Fourier transform infrared spectroscopy (FTIR) during Guangzhou Asian Games in 2010. The system structure and spectral quantitative analysis methods were introduced, and concentration results were analyzed. As a result, the cycle of hour average values of carbon monoxide and ozone concentrations had daily periodicity. There were several extreme values during monitoring period, which is still within national secondary standard. The hour average values of ethylene and acetylene concentrations changed synchronously, which should come from the same sources. The monitoring pollutants were not out of limits obviously throughout the Asian Games, during which the emission control measures were effective.

程巳阳, 高闽光, 徐亮, 冯明春, 童晶晶, 金岭, 李胜, 魏秀丽, 李相贤, 刘建国, 刘文清. 广州亚运会期间多组分污染气体的抽取式FTIR监测[J]. 大气与环境光学学报, 2011, 6(5): 351. CHENG Si-yang, GAO Min-guang, XU Liang, FENG Ming-chun, TONG Jing-jing, JIN Ling, LI Sheng, WEI Xiu-li, LI Xiang-xian, LIU Jian-guo, LIU Wen-qing. Polluted Multi-Gas Monitoring by Extraction FTIR During Guangzhou Asian Games[J]. Journal of Atmospheric and Environmental Optics, 2011, 6(5): 351.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!