首页 > 论文 > 大气与环境光学学报 > 6卷 > 5期(pp:398-402)

非制冷焦平面红外热像仪测温范围拓展研究

Extension of Temperature Range of Uncooled Infrared Imaging System

  • 摘要
  • 论文信息
  • 参考文献
  • 被引情况
  • PDF全文
分享:

摘要

非制冷焦平面红外热像仪其核心部件是红外焦平面阵列,以法国UILS公司生产的UL01011型非制冷焦平面红外探测器技 术参数为基础,其工作波长范围为8~14 μm,温度感测范围为-200℃。为拓展测温范围,在非制冷焦 平面红外热像仪前加装衰减波片,通过对不同衰减波片的实验数据的计算,得出不同条件下的测温范围,以完善其测量广度。

Abstract

Focal plane arrays is the core component of the uncooled infrared imaging system, based on the technical parameters of uncooled focal plane infrared detector produced by the French UILS UL01011. Its working wavelength is 8~14 μm, the temperature sensor range is -20℃0℃. To expand its sensing range, the glass attenuation is installed before the uncooled infrared absorption slide. By calculating the experimental data of the different glass attenuation, the temperature range under different conditions is obtained, so as to improve its measurementrange.

Newport宣传-MKS新实验室计划
补充资料

中图分类号:TN216

DOI:10.3969/j.issn.1673-6141.2011.05.012

收稿日期:2011-03-15

修改稿日期:2011-05-06

网络出版日期:--

作者单位    点击查看

刘纯红:安徽大学特种电视技术研究中心, 安徽 合肥 230088
吴海滨:安徽大学特种电视技术研究中心, 安徽 合肥 230088
王鹏:安徽大学物理与材料科学学院, 安徽 合肥 230039
周后伟:安徽大学物理与材料科学学院, 安徽 合肥 230039
张铁译:安徽大学物理与材料科学学院, 安徽 合肥 230039

联系人作者:刘纯红(redboy1110@yahoo.com.cn)

备注:刘纯红(1982-),男,硕士,主要从事特种工业电视系列产品的开发设计及图像信息处理方面的研究工作。

【1】Feng Yi, Wang jingzhong. The temperature compensation network of UFPA infrared detector [J]. Journal of Detection and Control, 2009, 31(2): 50-53(in Chinese).
冯祎, 王景中. 非制冷焦平面红外探测器的温控补偿网络 [J]. 探测与控制学报, 2009, 31(2): 50-53.

【2】Chang Benkang, Cai Yi. Infrared Imaging Array and System [M]. Beijing: Science Press, 2006(in Chinese).
常本康, 蔡 毅. 红外成像阵列与系统 [M]. 北京: 科学出版社, 2006.

【3】An Yuying, Liu Jifang, Li Qinghui. Photoelectron Technique [M]. Beijing: Electronics Industry Publisher, 2002(in Chinese).
安毓英, 刘继芳, 李庆辉. 光电子技术 [M]. 北京: 电子工业出版社, 2002.

【4】Fan Songbo, Li Qinghui, Lin Hong. Design of the temperature controlling for UFPA thermal camera [J]. Infrared and Laser Engineering, 2005, 34(4): 499-502(in Chinese).
樊松波, 李庆辉, 林 虹. 非制冷焦平面热像仪温度控制设计 [J]. 红外与激光工程, 2005, 34(4): 499-502.

【5】Ren Qi gan, Tan Qinhong. Design of temperature control system for uncooled focal plane detector based on ADN8830 [J]. Chinese Journal of Sensors and Actuators, 2010, 23(12): 1718-1721.
任其干, 谭钦红. 基于ADN8830的非制冷焦平面探测器温度控制系统设计 [J]. 传感技术学报, 2010, 23(12): 1718-1721(in Chinese).

引用该论文

LIU Chun-hong,WU Hai-bin,WANG Peng,ZHOU Hou-wei,ZHANG Tie-yi. Extension of Temperature Range of Uncooled Infrared Imaging System[J]. Journal of Atmospheric and Environmental Optics, 2011, 6(5): 398-402

刘纯红,吴海滨,王鹏,周后伟,张铁译. 非制冷焦平面红外热像仪测温范围拓展研究[J]. 大气与环境光学学报, 2011, 6(5): 398-402

被引情况

【1】刘纯红,吴海滨. 比色测温中外界环境误差的减小方法研究. 大气与环境光学学报, 2014, 9(6): 471-475

【2】吴海滨,张明,唐磊. 加热炉板坯表面温度与氧化皮温度鉴别方法. 大气与环境光学学报, 2014, 9(6): 476-481

您的浏览器不支持PDF插件,请使用最新的(Chrome/Fire Fox等)浏览器.或者您还可以点击此处下载该论文PDF