强激光与粒子束, 2011, 23 (9): 2356, 网络出版: 2011-10-27  

封闭式喷雾冷却系统启动时间

Startup time of closed loop spray cooling system
作者单位
中国石油大学(华东) 热能与动力工程系, 山东 青岛 266555
摘要
以蒸馏水为冷却工质,对冷凝器内置的封闭式光滑表面喷雾冷却系统进行了启动时间变化规律的实验研究,结果表明喷雾系统不同模块最优启动顺序为冷凝器、泵和加热器。采取6种不同的启动顺序,启动后加热表面的温度不均匀度均小于0.25 ℃。在最优启动顺序下,研究了冷却水流量、泵高度、加热功率和喷雾流量对启动时间的影响。随冷却水流量和喷雾流量增加启动时间缩短,随泵高度增加启动时间略微增大,随加热功率增大启动时间先增大后减小。启动时间影响程度由大到小的因素依次为喷雾流量、冷却水流量、加热功率及泵相对于加热表面的高度。喷雾工质流量由10 mL/min增大到35 mL/min时,封闭式喷雾系统的启动时间缩短了5 000 s。同样操作条件下,封闭式系统的启动时间比开放式系统延长15%~20%。
Abstract
Using water as coolant, a closed loop spray cooling system with a builtin condenser is established and the variation of startup time is measured dynamically. The optimized startup sequence for different modules is condenser, pump and heater. Under the optimized startup sequence, experimental investigation of the effect of operation parameters, such as cooling water flow rate, heating power, pump height and spray flow rate, on startup characteristics is made. The startup time decreases with the increase of the cooling water flow rate and spray flow rate. The descending order of influence of the factors is as follows: spray flow rate, cooling water flow rate, heating power, and relative height of pump. The startup time reduces by about 5 000 s when the spray flow rate increases from 10 mL/min to 35 mL/min. There exists a maximum of startup time with the variation of heating power. Under the same operation condition, the startup time of the closed loop system is 15% to 20% longer than that of the open one.

王照亮, 马永, 张伟, 赵欣. 封闭式喷雾冷却系统启动时间[J]. 强激光与粒子束, 2011, 23(9): 2356. Wang Zhaoliang, Ma Yong, Zhang Wei, Zhao Xin. Startup time of closed loop spray cooling system[J]. High Power Laser and Particle Beams, 2011, 23(9): 2356.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!