强激光与粒子束, 2011, 23 (10): 2836, 网络出版: 2011-11-18   

低抖动快前沿高电压重复率触发器

Repetitive trigger generator with low jitter and fast rise time
作者单位
西北核技术研究所, 西安 710024
摘要
介绍了一种低抖动、快前沿高电压重复率触发器,输出参数为:重复率可达100 pulse/s,输出时延约225 ns,抖动约1 ns,前沿约26 ns,脉宽约70 ns,高阻负载上电脉冲的峰值可达-40 kV,重复率为50 pulse/s时,峰值可达-51 kV,单次工作时的峰值可达-60 kV。该触发器主要由控制单元、高压供电单元与脉冲形成单元构成,脉冲形成单元采用了低电感电容对负载快放电的结构,建立开关为氢闸流管。实验发现,氢闸流管存在微导通状态,开关的通道电阻及维持的时间与开关极间的电势差有关;电势差越高,通道电阻越小,微导通状态维持的时间越长。此外,氢闸流管的导通性能受灯丝加热电源的影响明显,当加热电压较低时,氢闸流管导通缓慢,延时与抖动较大,当加热电压过高时,氢闸流管易于发生自击穿。
Abstract
A repetitive trigger generator with low jitter and fast rise time is introduced and the principles of designing and choosing the units in the trigger generator are given. The trigger generator is composed with control unit, charging unit and pulse forming unit. The pulse forming unit is a capacitor-fast-discharging trigger with hydrogen thyratron. The repetitive rate of trigger can reach 100 pps(pulses per second), the delay time is about 225 ns, the jitter is about 1 ns, the rise time is about 26 ns and the FWHM (full-width at half-magnitude) is about 70 ns. The amplitude of electrical pulse on the load with high impedance is about -40 kV at 100 pps, -51 kV at 50 pps, -60 kV at single shot, respectively. The micro-closing of hydrogen thyratron is discussed. As the anode voltage increases, the duration of micro-closing increases and the resistance of switch decreases. The effect of heating voltage on the breakdown characteristic of hydrogen thyratron is discussed as well.

尹佳辉, 曾江涛, 孙凤举, 张众, 魏浩, 刘志刚, 姜晓峰. 低抖动快前沿高电压重复率触发器[J]. 强激光与粒子束, 2011, 23(10): 2836. Yin Jiahui, Zeng Jiangtao, Sun Fengju, Zhang Zhong, Wei Hao, Liu Zhigang, Jiang Xiaofeng. Repetitive trigger generator with low jitter and fast rise time[J]. High Power Laser and Particle Beams, 2011, 23(10): 2836.

本文已被 4 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!