强激光与粒子束, 2012, 24 (1): 1, 网络出版: 2012-02-14
神光-Ⅲ主机激光装置片状放大器洁净控制进展
Development on cleanliness control of slab amplifiers for Shenguang-Ⅲ laser driver
摘要
针对神光-Ⅲ主机激光装置片状放大器的洁净控制采取了一系列有效措施。除了设计上更有利于洁净控制外, 机械结构件表面残留不挥发性有机污染物也达到了低于1 mg/m2的水平。为了进一步提高放大器洁净度, 进行了光照清洗。实验结果表明:神光-Ⅲ主机装置的洁净水平与美国国家点火装置接近, 光照清洗时内部气溶胶等级维持在5 000~10 000之间, 且绝大部分表面有机残留物在最初几发光照清洗中已被释放, 从而得到一个干净的放大器腔体, 减少了放大器运行时光学元件受污染和损伤的几率。
Abstract
A contamination control plan was introduced to improve the cleanliness of slab amplifiers for Shenguang-Ⅲ laser driver, including laser structure optimization and precision cleaning methods, and the non-volatile-residue amount on the surface of mechanical structures was lower than 1 mg/m2 after precision cleaning. The illuminating cleaning experiment by flashlamp light was introduced to further improve the facility’s cleanliness. The results indicate that the cleanliness of Shenguang-Ⅲ laser driver is close to that of NIF, but better than other similar devices in the world. The aerosol concentration in Shenguang-Ⅲ amplifier cavity during flashlamp shots maintained among 5 000 to 10 000 particles (larger than 0.5 μm) per cubic foot, and most of the surface organic residue was released at the first few shots and a clean amplifier was obtained finally. The significant improvements in cleanliness have provided a strong guarantee for the safe operation of Shenguang-Ⅲ laser driver.
程晓锋, 苗心向, 陈远斌, 王洪彬, 秦朗, 吕海兵, 熊迁, 贺群, 马志强, 叶亚云, 赵龙彪, 刘勇, 贺少勃, 袁晓东, 朱启华, 景峰, 郑万国. 神光-Ⅲ主机激光装置片状放大器洁净控制进展[J]. 强激光与粒子束, 2012, 24(1): 1. Cheng Xiaofeng, Miao Xinxiang, Chen Yuanbin, Wang Hongbin, Qin Lang, Lü Haibing, Xiong Qian, He Qun, Ma Zhiqiang, Ye Yayun, Zhao Longbiao, Liu Yong, He Shaobo, Yuan Xiaodong, Zhu Qihua, Jing Feng, Zheng Wanguo. Development on cleanliness control of slab amplifiers for Shenguang-Ⅲ laser driver[J]. High Power Laser and Particle Beams, 2012, 24(1): 1.