强激光与粒子束, 2012, 24 (1): 193, 网络出版: 2012-02-14  

含散射闪光照相系统的布局优化

Layout optimization for flash radiography with scatter
作者单位
中国工程物理研究院 流体物理研究所, 四川 绵阳 621900
摘要
为了提高现有照相系统的图像品质, 对使用CCD探测器的法国客体(FTO)照相布局进行了优化, 获得最佳图像品质因子下的照相布局。研究结果为:在模糊实验测量结果和高斯分布近似下, 系统放大倍率为2.0;后保护器件距离客体50 cm;系统布局总长与探测系统的噪声相关, 噪声越大, 布局总长越短, 最优布局总长的范围为3~5 m;实验验证了这一结果。
Abstract
The paper investigates the layout optimization for flash radiography with scatter using CCD to improve the imaging quality. The best layout is gained with the best factor of merit. The best magnification of the radiography system is 2 with the experimentally measured blur and Gaussian style assumption. The distance from the object to back windows is 50 cm. The best system length is related to the noise, and more noise leads to shorter system. The range of the best length is 3 to 5 m. The test has verified the above results.

刘进, 刘军, 章林文, 施将君. 含散射闪光照相系统的布局优化[J]. 强激光与粒子束, 2012, 24(1): 193. Liu Jin, Liu Jun, Zhang Linwen, Shi Jiangjun. Layout optimization for flash radiography with scatter[J]. High Power Laser and Particle Beams, 2012, 24(1): 193.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!