光学 精密工程, 2012, 20 (2): 264, 网络出版: 2012-03-06  

光纤色散法测量闪烁体脉冲光谱

Measurement of pulse spectra for scintillator based on fiber dispersion
作者单位
西北核技术研究所,陕西 西安 710024
摘要
提出了一种利用光纤波长色散测量脉冲光谱的方法。由于具有较宽光谱的脉冲光在一定长度的光纤中传播时会发生波形展宽,需要根据测量和标定结果校正展宽的波形才能得到光源的实际光谱曲线。标定时首先利用ps级脉冲光源对测量系统进行时间响应标定,得到系统的时间响应函数; 接着测量不同波长光的走时,得到不同波长的群折射率; 最后测量光纤中的光谱衰减,得到各种波长的相对衰减或传输效率。利用以上3个标定结果,对波形进行数字逆卷积,并进行走时校正和衰减系数校正,即可对所得到的波形进行恢复。经实验测量和数据处理,得到了一种红光闪烁体的发光光谱曲线,其中心波长与用其他方法测到的中心波长的差小于2 nm,谱线形状基本一致。研究显示,在脉冲光的脉冲宽度远小于其色散展宽时,可以利用光纤的波长色散对脉冲光的光谱进行测量。
Abstract
A new method to measure the spectrum of a pulse light was developed. As the pulse width could be broaden due to the dispersion when a pulse light passed through the optical fiber, the calibration and measurement were proposed to correct and recover the broaden waveform to obtain the real spectrum of a pulse light source. In calibration, the time response function of measuring system was gotten with a ps laser firstly; then the group refractive indexes at different wavelengths were obtained by measuring the time delay of given wavelengths; finally, the relative attenuation index of each wavelength in optical fiber was given by measuring the spectral attenuation. On the basis of the calibration results mentioned above, broaden waveform was recovered by the digital deconvolution, time delay and attenuation .The pulse spectrum of a red scintillator was measured with this method. Results demonstrate that the difference of the center wavelength of the scintillator given by this method and other methods is less than 2 nm, which shows the spectra of pulse light can be measured based on fiber dispersion when the pulse width is much less than its dispersion.

魏福利, 王培伟. 光纤色散法测量闪烁体脉冲光谱[J]. 光学 精密工程, 2012, 20(2): 264. WEI Fu-li, WANG Pei-wei. Measurement of pulse spectra for scintillator based on fiber dispersion[J]. Optics and Precision Engineering, 2012, 20(2): 264.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!