直接正交信号校正算法在烷烃类多组分气体定量分析中的应用

Application of Direct Orthogonal Signal Correction Algorithm in Multi-Component Alkane Quantitative Analysis
作者单位
1 西安理工大学自动化与信息工程学院, 陕西 西安710048
2 西安交通大学电气工程学院, 陕西 西安710049
摘要
针对烷烃类多组分混合气体中红外光谱存在的基线漂移问题, 提出一种直接正交信号校正算法用于光谱数据预处理。 实验中采用傅里叶变换红外光谱仪采集了936组混合气体样本的光谱数据, 混合气体主要由不同浓度范围的七种组分气体组成。 将直接正交信号校正算法与导数算法进行了对比分析, 采用偏最小二乘回归方法建立了各组分气体定量分析模型, 并对模型参数(主元个数、 导数步长及正交分量的个数)进行了遍历优化选取最优分析模型。 结果表明直接正交信号校正算法对于中红外光谱基线校正效果最好, 直接正交信号校正算法用于烷烃类混合气体中红外光谱基线校正可行, 效果良好, 具有一定的实用和研究价值。
Abstract
According to the baseline departure of multi-component alkane gas mixture spectra, direct orthogonal signal correction (DOSC) algorithm was proposed to pretreat the infrared spectra data. Fourier transform infrared (FTIR) spectrometer was used to sample 936 spectra data of seven components gas mixture, including methane, ethane, propane, iso-butane, n-butane, iso-pentane and n-pentane gases. The concentration of each component ranges from 0.01% to 0.1%, 0.01% to 0.1%, 0.01% to 0.15%, 0.0% to 0.1%, 0.0% to 0.1%, 0.0% to 0.05%, and 0.0% to 0.05%, respectively. For analyzing intuitively, partial least square regression (PLSR) was introduced to build the component gas quantitative analysis model. In experiment, DOSC method was compared with first derivative algorithm (FDA) and second derivative algorithm (SDA). In order to get the optimal model, ergodic optimization method was used to select the optimal parameters of the model, i.e. the step of the derivative algorithm, the number of the primary component of the PLSR and the number of orthogonal components of the DOSC algorithm. The experiment results show that DOSC algorithm has the better effect in the field of infrared spectra data pretreating. The average mean relative error (MRE) of the component gas analysis models is 16.58%, which declined by 66.80% from the average MRE before data pretreating 49.93%. Compared with DA, the average MRE declined by 51.51% from 34.19% after pretreated by FDA, and declined by 56.30% from 37.94% after pretreated by SDA. So DOSC method is feasible to pretreat the IR spectra data, and has definite practical and investigation value.

李玉军, 汤晓君, 刘君华. 直接正交信号校正算法在烷烃类多组分气体定量分析中的应用[J]. 光谱学与光谱分析, 2012, 32(4): 1038. LI Yu-jun, TANG Xiao-jun, LIU Jun-hua. Application of Direct Orthogonal Signal Correction Algorithm in Multi-Component Alkane Quantitative Analysis[J]. Spectroscopy and Spectral Analysis, 2012, 32(4): 1038.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!