摘要
以大面阵彩色CCD航测相机为研究对象,分析其成像过程,提出了影响相机辐射响应特性的各个因素,并以此为基础,建立了辐射响应特性模型。分别在暗场和使用积分球的条件下进行了辐射响应标定实验,通过组合更改输入辐亮度、曝光时间和CCD增益等因素对相机的辐射响应特性进行测量和分析。结果表明,相机R、G、B颜色通道随输入辐亮度变化的辐射响应特性并不相同,但在工作谱段范围内均呈线性变化趋势。采用最小二乘法对辐射标定数据进行拟合,一次多项式拟合结果的决定系数R2值均可达到0.999以上。当输入辐亮度不变时,相机输出图像灰度值随曝光时间或CCD增益的变化呈线性变化趋势,从而为其它工作条件下辐射响应特性曲线的推演奠定了理论基础。将相机辐射响应标定结果应用于相机调光功能,成像结果表明,获得的图像亮度适中,图像平均灰度值满足调光要求。
Abstract
Several kinds of factors affecting the radiometric calibration of a large area array color CCD aerial mapping camera were presented through analyzing the process of camera imaging. Then,a model for radiometric calibration was established. The experiments of radiometric calibration were performed by using integrating sphere and in the dark field, respectively, and outputs of radiometric response of the camera were measured and analyzed through combination of changing the input radiance, exposure time, CCD gain and other factors. The experimental results show that the characteristics of radiometric response for R, G and B color channels are different when the input radiance is changed, but it varies linearly in the working spectral range. When the least square method is used to fit the calibration data of radiation, the goodness of fit for first-order polynomial shows that the R2 is above 0.999. Furthermore,when input radiometric luminance is constant,the output of the camera varies linearly with the exposure time or CCD gain, which lays the theoretical basis for the deduction of radiation response characteristic curves under the other work conditions. The data from radiometric calibration is applied to the exposure parameters, and experimental results indicate that the lightness of image is appropriate and its average gray value satisfies the requirement for exposure.

修吉宏, 黄浦, 李军, 李友一. 大面阵彩色CCD航测相机的辐射定标[J]. 光学 精密工程, 2012, 20(6): 1365. XIU Ji-hong, HUANG Pu, LI Jun, LI You-yi. Radiometric calibration of large area array color CCD aerial mapping camera[J]. Optics and Precision Engineering, 2012, 20(6): 1365.

本文已被 15 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!