强激光与粒子束, 2013, 25 (12): 3115, 网络出版: 2013-12-16   

实验靶对半黑腔辐射源辐射温度的影响

Influence of different targets on halfraum radiation source temperature
作者单位
中国工程物理研究院 激光聚变研究中心, 四川 绵阳 621900
摘要
间接驱动惯性约束聚变和高能量密度物理实验中使用黑腔作为强X射线辐射源,黑腔源靶的等效辐射温度受安装在辐射出口的实验用靶的影响而与单独进行辐射源特性研究时有所不同。通过对几种不同辐射输运靶对半黑腔辐射源的影响进行的实验研究发现,添加不同填充材料的输运管能够使测量到的黑腔辐射源的辐射温度升高3~8 eV。实验结果的统计显示,输运管越长,填充材料密度越大,辐射温度越高。
Abstract
Hohlraums/halfraums are used as intensive X-ray radiation sources in indirect drive inertial confinement fusion and high energy density physics experiments to study material properties and physical problems like radiation transport. The equivalent radiation temperatures of the hohlraums are different from those with experimental targets attached on the wall. Experiments are carried out to study influence of different types of foam-filled cylinders attached to the halfraum bottom and 3-8 eV increase of the halfraum radiation source temperature is found. The statistics show that the radiation temperatures are higher with longer and denser-foam-filled cylinders.

宋天明, 杨家敏, 朱托, 易荣清, 黄成武. 实验靶对半黑腔辐射源辐射温度的影响[J]. 强激光与粒子束, 2013, 25(12): 3115. Song Tianming, Yang Jiamin, Zhu Tuo, Yi Rongqing, Huang Chengwu. Influence of different targets on halfraum radiation source temperature[J]. High Power Laser and Particle Beams, 2013, 25(12): 3115.

本文已被 1 篇论文引用