强激光与粒子束, 2013, 25 (12): 3139, 网络出版: 2013-12-16   

神光Ⅱ升级装置软X光能谱仪研制

Development of soft X-ray energy spectrometer on Shenguang Ⅱ-up equipment
作者单位
中国工程物理研究院 激光聚变研究中心, 四川 绵阳 621900
摘要
软X光能谱仪(SXS)是惯性约束聚变黑腔辐射流、辐射温度测量的主要诊断设备。根据神光Ⅱ升级装置实验需求,完成软X光谱仪系统研制,并开展了性能研究。谱仪采用环形透镜成像准直方法保证瞄准精度,通过固定角度平面镜安装机构来减少角度偏差。利用滤片、平面镜以及X光二极管(XRD)探测器的标定实验结果,得到谱仪测量能区为0.05~4.97 keV。在短脉冲激光装置上开展通道时间响应性能研究,确定系统时间分辨力为99.22 ps。
Abstract
Soft X-ray energy spectrometer (SXS) is an important instrument for radiation temperature measurement. According to Shenguang Ⅱ-up experimental requirements, the 15-channel soft X-ray energy spectrometer has been developed and its performances have been studied. The spectrometer’s structure has been improved. Circularity convex has been used to image the target for precise collimation, and angle-changeless setup has been adopted to avoid mirrors angle error. Filters, mirrors and X-ray diodes (XRDs) have been calibrated on synchrotron radiation facility. The results show that SXS spectrum range is 0.05-4.97 keV. And the temporal performances have been studied on the short-pulse laser facility. The temporal resolution achieves to 99.22 ps.

侯立飞, 李军, 杜华冰, 崔延莉, 宋天明, 韦敏习, 杨轶濛, 李三伟, 易荣清, 易涛, 杨国洪, 刘慎业, 江少恩. 神光Ⅱ升级装置软X光能谱仪研制[J]. 强激光与粒子束, 2013, 25(12): 3139. Hou Lifei, Li Jun, Du Huabing, Cui Yanli, Song Tianming, Wei Minxi, Yang Yimeng, Li Sanwei, Yi Rongqing, Yi Tao, Yang Guohong, Liu Shenye, Jiang Shao’en. Development of soft X-ray energy spectrometer on Shenguang Ⅱ-up equipment[J]. High Power Laser and Particle Beams, 2013, 25(12): 3139.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!