大气与环境光学学报, 2014, 9 (1): 61, 网络出版: 2014-02-18
高光谱成像仪交叉定标技术研究及应用
Research and Application of Cross-Calibration Technology Based on Hyperspectral Imager
摘要
针对高光谱成像仪的在轨定标,提出三种交叉定标技术方案,分析了时相匹配、视场匹配、光谱匹配和几何匹配等 交叉定标过程中的关键单元技术,结合HJ-1A/HSI、EO-1/Hyperion等开展了交叉定标算法模型验证。通过 这三种技术方案的应用,与场地定标相结合,将有利于提高在轨定标的频次、快速校验场地定标系数,有效 提升高光谱数据的定量化应用水平。
Abstract
Due to the need of post-launch calibration of hyperspectral imagers, three cross-calibration technical solutions are proposed. Matching technologies including field, time, geometry and spectrum in the process of cross-calibration are analysed. Algorithms and models in matching technologies are validated by the use of the data of HJ-1A/HSI, EO-1/Hyperion. By the application of three technical solutions with site-calibration method, the frequency of post-launch calibration can be improved and site-calibration coefficients can be validated quickly. The level of quantitative application of hyperspectral data can be promoted effectively.
徐文斌, 郑小兵, 易维宁, 李健军, 史剑民. 高光谱成像仪交叉定标技术研究及应用[J]. 大气与环境光学学报, 2014, 9(1): 61. XU Wen-bin, ZHENG Xiao-bing, YI Wei-ning, LI Jian-jun, SHI Jian-min. Research and Application of Cross-Calibration Technology Based on Hyperspectral Imager[J]. Journal of Atmospheric and Environmental Optics, 2014, 9(1): 61.