中国光学, 2015, 8 (3): 464, 网络出版: 2015-07-10   

拼接式编码器测角误差分析及试验

Error analysis and experimentation of scale tape encoder
作者单位
1 中国科学院 光电技术研究所, 四川 成都 610209
2 中国科学院大学, 北京 100049
摘要
根据望远镜测角系统的精度需求, 分析了影响拼接式编码器测角精度的误差源, 以及多读数头测角消差原理, 确定了采用相位相差90°的4读数头的测角方式。在某望远镜方位轴系转台进行了逆时针和顺时针方向的测角试验, 通过对测角数据进行谐波分析并补偿后, 得到两组实验测角误差RMS分别为0.34″、0.38″。实验表明, 相位相差90°的均布4读数头的测角方式消除了由轴系误差、编码器安装位置误差和钢带安装盘部分圆度误差对测角精度的影响, 实现了亚角秒级测角的目的。研究结果可用于大口径望远镜设计阶段的误差分析与分配、预估测角精度, 为降低设计和加工误差提供参考。
Abstract
According to the accuracy specifications of telescope goniometry, error sources of sacle tape grating encoder and the angle measuring principle of multi reading head are analyzed. A 4-reading heads angle measurement program which have 90° phase difference, have been developed. And we make counterclockwise and clockwise angle measuring experiments on an azimuth turntable of telescope through harmonic processing and error compensation, and two sets of experiments measuring angle error RMS values of 0.42″ and 0.41″ are obtained. Experiment results show that the effect of shafting errors, processing error of installation position and partly roundness error for installation torus on the angular measurement accuracy is eliminated by harmonic processing and phase difference method, and high precision angle measurement with sub-arc-second-accuary is achieved. The research results are useful for analyzing and distributing errors, forecasting angle measuring accuracy and reducing design and machining errors in the design of large aperture telescopes.

黄龙, 潘年, 马文礼, 黄金龙. 拼接式编码器测角误差分析及试验[J]. 中国光学, 2015, 8(3): 464. HUANG Long, PAN Nian, MA Wen-li, HUANG Jin-long. Error analysis and experimentation of scale tape encoder[J]. Chinese Optics, 2015, 8(3): 464.

本文已被 2 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!