强激光与粒子束, 2015, 27 (12): 122001, 网络出版: 2015-12-18  

18~88keVRoss滤片谱仪的设计和应用

Design and application of Ross filter spectrometer covering 18-88 keV
作者单位
1 中国工程物理研究院 激光聚变研究中心, 四川 绵阳 621900
2 清华大学 工程物理系, 北京 100084
3 北京大学 应用物理与技术研究中心, 北京 100871
摘要
以带通平响应为优化目标,通过残余响应、带外残余响应相对误差以及残余响应平整度3个参数来优化滤片的厚度,设计了一套共有7个能量通道、连续覆盖18~88 keV能谱范围的Ross滤片谱仪。该谱仪能量通道宽度在2~20 keV之间。多数能量通道的带外残余响应相对误差低于10%,残余响应平整度优于20%。将该谱仪应用于微聚焦X光机上的高Z金属球壳高能X射线背光照相实验,结果表明:在不同的实验条件下,Ross滤片谱仪测得的能谱形状与理论模型给出的结果符合较好,测得的能谱不仅能够很好地解释背光照相图像,而且可用于根据图像反推客体的面密度。
Abstract
A Ross filter spectrometer, consisting of 7 energy channels and covering 18-88 keV energy range, was designed by calculation with the optimization goal of band-pass flat response, in which the residual response, relative error outside the energy channels and flatness inside energy channels were used to optimize the thickness of the filters. The energy channel width of the spectrometer was between 2 keV and 20 keV. The relative error and flatness were lower than 10% and 20% respectively for most energy channels. This spectrometer was applied to experiments performed on a microfocus X-ray tube in which high-energy X-ray was used to backlit spherical shell samples made of high-Z metals. The results show that, under different experimental conditions, spectra measured by Ross filter spectrometer were in agreement with theory models. The measured spectra interpreted the images quite well and could be used to obtain areal density from the images.

郑建华, 晏骥, 韦敏习, 江少恩. 18~88keVRoss滤片谱仪的设计和应用[J]. 强激光与粒子束, 2015, 27(12): 122001. Zheng Jianhua, Yan Ji, Wei Minxi, Jiang Shaoen. Design and application of Ross filter spectrometer covering 18-88 keV[J]. High Power Laser and Particle Beams, 2015, 27(12): 122001.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!