Abstract

This work proposes a method to concurrently calibrate multiple acoustic speeds in different mediums with a photoacoustic (PA) and ultrasound (US) dual-modality imaging system. First, physical infrastructure information of the target is acquired through a US image. Then, we repeatedly build PA images around a special target to yield the best focused result by dynamically updating the acoustic speeds in a different medium of the target. With these correct acoustic propagation velocities in the according mediums, we can effectively optimize the PA image quality as the experiments proved, which might benefit future research in biomedical imaging science.

Newport宣传-MKS新实验室计划
补充资料

DOI:10.3788/col201614.081701

所属栏目:Medical optics and biotechnology

收稿日期:2016-03-23

录用日期:2016-06-14

网络出版日期:2016-07-14

作者单位    点击查看

Meng Ye:School of Electronic Science and Engineering, Nanjing University, Nanjing 21 0093, China
Meng Cao:School of Electronic Science and Engineering, Nanjing University, Nanjing 21 0093, China
Jie Yuan:School of Electronic Science and Engineering, Nanjing University, Nanjing 21 0093, China
Yudi Chen:School of Physics, Tongji University, Shanghai 2 00092 , China
Qian Cheng:School of Physics, Tongji University, Shanghai 2 00092 , China
Chao Tao:School of Physics, Nanjing University, Nanjing 210093 , China
Xiaojun Liu:School of Physics, Nanjing University, Nanjing 210093 , China
Guan Xu:Department of Radiology, University of Michigan, Ann Arbor 4 8109, USA
and Xueding Wang:Department of Radiology, University of Michigan, Ann Arbor 4 8109, USA

联系人作者:联系作者(yuanjie@nju.edu.cn)

备注:This work was supported by National Natural Science Foundation of China (No. 61201425), the Natural Science Foundation of Jiangsu Province (No. BK20131280), and the Priority Academic Program Development of Jiangsu Higher Education Institutions.

【1】M. Xu, and L. V. Wang, Rev. Sci. Instrum.77, 22 (2006).

【2】G. Torres, K. J. Parker, B. Castaneda, and R. Lavarello, Int. Ultrason. Symp.0380, 1 (2015).

【3】J. Jose, R. G. Willemink, W. Steenbergen, C. H. Slump, T. G. van Leeuwen, and S. Manohar, Med. Phys.39, 7262 (2012).

【4】Y. Liu, L. Nie, and X. Chen, Trends Biotechnol.34, 420 (2016).

【5】Y. Wang, J. Yuan, S. Du, X. Liu, G. Xu, and X. Wang, Chin. Opt. Lett.13, 061001 (2015).

【6】J. Xia, J. Yao, and L. V. Wang, Electron. Waves147, 1 (2014).

【7】L. V. Wang, and S. Hu, Science335, 1458 (2012).

【8】R. X. Cheng, C. Tao, and X. J. Liu, Chin. Phys. B.24, 11 (2015).

【9】B. Cong, K. Kondo, M. Yamakawa, and T. Shiina, in IEEE Int. Ultrason. Symp.1368 (2014).

【10】H. He, and D. C. Liu, in ICBBE International Conference on Bioinformatics and Biomedical Engineering-IEEE1 (2009).

【11】B. E. Treeby, E. Z. Zhang, and B. T. Cox, Inverse Prob.26, 115003 (2010).

【12】K. Wang, T. Matthews, F. Anis, C. Li, N. Duric, and M. Anastasio, Ultra. Ferr. Freq. Con.62, 475 (2015).

【13】C. Huang, K. Wang, L. Nie, L. V. Wang, and M. A. Anastasio, IEEE Med. Imag.32, 1097 (2013).

【14】J. Yao, J. Xia, K. I. Maslov, M. Nasiriavanaki, V. Tsytsarev, A. V. Demchenko, and L. V. Wang, NeuroImage64, 257 (2013).

【15】M. Cao, J. Yuan, S. Du, G. Xu, X. D. Wang, P. L. Carson, and X. J. Liu, Biomed. Sig. Proc. Con.21, 19 (2015).

【16】X. Liu, D. Peng, X. Ma, W. Guo, Z. Liu, D. Han, X. Yang, and J. Tian, Appl. Opt.52, 3477 (2013).

【17】H. Huang, G. Bustamante, R. Peterson, and J. Y. Ye, Med. Phy.42, 2169 (2015).

【18】C. W. Wei, T. M. Nguyen, J. Xia, B. Arnal, E. Y. Wong, I. M. Pelivanov, and M. O’Donnell, Ultra. Ferr. Freq. Con.62, 319 (2015).

【19】H. Ke, T. N. Erpelding, L. Jankovic, C. Liu, and L. V. Wang, J. Bio. Opt.17, 056010 (2012).

【20】J. Yin, C. Tao, P. Cai, and X. Liu, Appl. Phys. Lett.106, 234101 (2015).

【21】E. Malone, S. Powell, B. T. Cox, and S. Arridge, J. Biomed. Opt.20, 126004 (2015).

【22】C. Yoon, J. Kang, S. Han, Y. Yoo, T. K. Song, and J. H. Chang, Opt. Express20, 3082 (2012).

【23】A. M. Kingston, A. Sakellariou, A. P. Sheppard, T. K. Varslot, and S. J. Latham, Proc. SPIE7804, 78040J (2010).

【24】C. Huang, L. Nie, R. W. Schoonover, L. V. Wang, and M. A. Anastasio, J. Biomed. Opt.17, 061211 (2012).

【25】M. Kim, J. Kang, J. H. Chang, T. K. Song, and Y. Yoo, IEEE Int. Ultrason. Symp.0388, 1528 (2013).

【26】W. C. Vogt, C. Jia, K. A. Wear, B. S. Garra, and T. J. Pfefer, J. Biom. Opt.21, 101405 (2016).

【27】B. Cong, K. Kondo, M. Yamakawa, and T. Shiina, IEEE Int. Ultrason. Symp.0388, 1368 (2014).

引用该论文

Meng Ye, Meng Cao, Jie Yuan, Yudi Chen, Qian Cheng, Chao Tao, Xiaojun Liu, Guan Xu, and Xueding Wang, "Adaptive speed of sound correction with photoacoustic tomography for imaging quality optimization," Chinese Optics Letters 14(8), 081701 (2016)

您的浏览器不支持PDF插件,请使用最新的(Chrome/Fire Fox等)浏览器.或者您还可以点击此处下载该论文PDF