摘要
武威重离子治癌装置回旋注入系统由自重50余吨的回旋加速器和离子源等多个元件组成,由于离子源和回旋加速器的上下共架结构及回旋注入系统自身过于紧凑等原因,给各元件的安装准直工作增加了难度。借助于激光跟踪仪和三维控制网,通过自下而上分级准直安装及高空架设仪器的方法,克服了通视条件不足等困难,有效提高了工作效率,所有的安装元件误差都控制在0.10 mm以内,其结果好于该装置的安装精度要求。回旋注入系统已成功出束,各项指标均已达到或优于设计指标,从而验证了准直安装工作的准确性与可行性。
Abstract
The Cyclotron Injection System of the Wuwei Heavy Ion Medical Machine consists of a cyclotron that has a weight more than 50 tons, an ion source and some auxiliary facilities. As the ion source and the cyclotron use one girder and have a very tight construction, it is difficult to install and align the system. By the aid of a laser tracker and a three-dimensional control network, through step by step survey and alignment from bottom to top, our method improves the work efficiency of alignment and guarantees a 0.10 mm deviation for each finally installed magnet in each direction. The results are better than the installation precision demands of the Heavy Ion Medical Machine. Currently, the cyclotron injection system has been successfully commissioned and the performance is proved well, and some indexes are better than the design targets, which also verify that the method used for this system has a high accuracy and feasibility.

陈文军, 马力祯, 蔡国柱, 崔治国, 张小奇, 袁建东, 王少明, 华永平, 柴一亮. 武威重离子治癌装置回旋注入系统的准直安装[J]. 强激光与粒子束, 2016, 28(10): 106003. Chen Wenjun, Ma Lizhen, Cai Guozhu, Cui Zhiguo, Zhang Xiaoqi, Yuan Jiandong, Wang Shaoming, Hua Yongping, Chai Yiliang. Survey and alignment for cyclotron injection system of the Wuwei Heavy Ion Medical Machine[J]. High Power Laser and Particle Beams, 2016, 28(10): 106003.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!