Photonics Research, 2016, 4 (2): 02000074, Published Online: Sep. 28, 2016  

Wavelet modulus maxima method for on-line wavelength location of pulsed lidar in CO2 differential absorption lidar detection Download: 585次

Author Affiliations
1 State Key Laboratory of Information Engineering in Surveying, Mapping and Remote Sensing, Wuhan University, Luoyu Road 129, Wuhan 430079, China
2 Collaborative Innovation Center for Geospatial Technology, Wuhan 430079, China
3 Hubei Collaborative Innovation Center for High-efficiency Utilization of Solar Energy, Wuhan 430068, China
4 School of Remote Sensing and Information Engineering, Wuhan University, Luoyu Road 129, Wuhan 430079, China
5 e-mail: maofeiyue@whu.edu.cn
Abstract
Differential absorption lidar (DIAL) is an excellent technology for atmospheric CO2 detection. However, the accuracy and stability of a transmitted on-line wavelength are strictly required in a DIAL system. The fluctuation of a tunable pulsed laser system is relatively more serious than that of other laser sources, and this condition leads to a large measurement error for the lidar signal. These concerns pose a significant challenge in on-line wavelength calibration. This study proposes an alternative method based on wavelet modulus maxima for the accurate on-line wavelength calibration of a pulsed laser. Because of the different propagation characteristics of the wavelet transform modulus maxima between signal and noise, the singularities of a signal can be obtained by detection of the local modulus maxima in the wavelet transform maximum at fine scales. Simulated analysis shows that the method is more accurate than the general method such as quintic polynomial fitting and can steadily maintain high calibration precision at different signal-to-noise ratios (SNRs). Last, 16 groups of real experiments were conducted to verify the simulated analysis, which shows that the proposed method is an alternative for accurately calibrating an on-line wavelength. In addition, the proposed method is able to suppress noises in the process of wavelength calibration, which gives it an advantage in accurate on-line wavelength calibration with a low SNR.Research Funds for the Central Universities (2042015kf0015).

Wei Gong, Chengzhi Xiang, Feiyue Mao, Xin Ma, Ailin Liang. Wavelet modulus maxima method for on-line wavelength location of pulsed lidar in CO2 differential absorption lidar detection[J]. Photonics Research, 2016, 4(2): 02000074.

引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!