红外技术, 2016, 38 (12): 1067, 网络出版: 2017-01-03   

半透明体后被测物体红外辐射测温误差分析

Temperature Measurement Error Analysis of Infrared Radiation of the Object Being Measured After Semitransparent Object
作者单位
海军工程大学动力工程学院, 湖北 武汉 430033
摘要
根据红外辐射理论和红外热成像仪的测温原理,考虑环境、大气、物体透射辐射等多方面影响,建立了红外热像仪对半透明体后被测物体测温的数学模型,分析了半透明体反射率、透射率及其误差、被测物体发射率及其误差对热像仪测温误差的影响,提出了减少半透明体后被测物体红外辐射测量误差的几种对策,提出了提高带红外检测窗口电气柜中带电部件的红外测温准确性的方法。
Abstract
Based on the theory of infrared radiation and the infrared thermography, the mathematical correction model of the infrared radiation temperature measurement of the object to be measured after the semitransparent object is established with the effects caused by the atmosphere, surroundings, radiation of transimissivity and many other factors taken account of. The effects of the emissivity, transimissivity and measurement error are analyzed on temperature measurement error of the infrared thermography. Several strategies for reducing the error of infrared radiation measurement of the transmission medium for the semitransparent object are presented. Several methods for improving the accuracy of infrared temperature measurement of the charged components in the electrical cabinet with infrared detection window are presented.

赵小龙, 杨立, 苗雨. 半透明体后被测物体红外辐射测温误差分析[J]. 红外技术, 2016, 38(12): 1067. ZHAO Xiaolong, YANG Li, MIAO Yu. Temperature Measurement Error Analysis of Infrared Radiation of the Object Being Measured After Semitransparent Object[J]. Infrared Technology, 2016, 38(12): 1067.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!