中国光学, 2017, 10 (2): 234, 网络出版: 2017-04-10   

激光微角偏移测试系统研究

Laser micro angular deviation measurement system
作者单位
中北大学 理学院, 山西 太原 030051
摘要
针对火炮出厂前的校瞄工作存在自动化程度不高、测试结果分辨率和精度低的缺点, 设计了一种新型激光微角偏移测试校瞄系统。该系统由位置灵敏探测器(PSD)、准直平行激光管与二维精密旋转控制器构成。采用光电转换和信号处理技术, 可实时获取火炮身管轴线的微角偏移量; 利用相对简单的方法完成了高精度的测试, 有效地改善了传统校瞄方法的不足。实验测试结果表明, 该系统可在炮管仰角0°~70°范围内全程测试微角偏移量, 其分辨率可达到0.001°, 可广泛应用于不同口径火炮身管轴线的校瞄工作中。
Abstract
There are some shortcomings in aiming correction before the artillery leaves the factory, just like the low degree of automation, the low resolution and accuracy. Aiming at these problems, we design a novel laser micro angular deviation measurement and proofread aiming system. The system consists of position sensitive detector(PSD), collimating parallel laser tube and two-dimensional precision spin controller, and the micro angle offset of artillery bore can be acquired in real-time using the photoelectric conversion and signal processing technology. The traditional proofread aiming method can be improved effectively using relatively simple means to complete the high precision measurement. Experimental test results show that the system can detect the micro angle deviation with the barrel elevation range of 0°~70° in the whole course, and its resolution can reach 0.001°. It can be widely used to proofread aiming with different caliber artillery bore.

韩宝章, 李亦军. 激光微角偏移测试系统研究[J]. 中国光学, 2017, 10(2): 234. HAN Bao-zhang, LI Yi-jun. Laser micro angular deviation measurement system[J]. Chinese Optics, 2017, 10(2): 234.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索