Abstract
Pulse contrast is an important parameter for ultrafast pulses. It shall be 108 or higher in order to avoid effect from noise before main pulse. Diagnostics with cross-correlation can achieve high temporal resolution such as ~7fs. Cross-correlation has advantage in pulse contrast measurement than autocorrelation because it can distinguish noise before or after main pulse. High dynamic range is also essential in pulse contrast measurement. Cross-correlation signal from a single shot is converted into a signal series through fiber array, which can be analyzed by a set of a PMT and an oscilloscope. Noise from nonlinear crystal and scatter needs decrease to improve dynamic range. And pulse power is also discussed in pulse contrast experiments. Time delay τ is generated by travel stage in measurement for repetition pulses. Then energy instability will generate error in this measurement. In measurement for single shot pulse, time delay τ is generated by slant angle of beams. The scanning procession is completed with thousands parts of beam section within a single shot, and error will generated from no uniformity in near field. Performance test of pulse contrast measurement is introduced in subsequent sections. Temporal resolution is testified by self-calibration. Dynamic range is judged by a parallel flat. At last pulse contrast of petawatt laser is diagnosed by a single shot cross-correlator with high confidence. The ratio is 10-6 at 50ps before main pulse, and 10-4 at 10ps before main pulse.

Xiaoping Ouyang, Daizhong Liu, Baoqiang Zhu, Jian Zhu, Jianqiang Zhu. Diagnostics of pulse contrast for p etawatt laser in SGII[J]. Collection Of theses on high power laser and plasma physics, 2015, 13(1): 93450R.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!