光谱学与光谱分析, 2017, 37 (3): 755, 网络出版: 2017-06-20  

近红外光谱法快速测定工作场所莠去津浓度的研究

Rapid Detection of Atrazine at Workplace with Near-Infrared Spectroscopy
作者单位
1 职业安全健康北京市重点实验室, 北京市劳动保护科学研究所, 北京 100054
2 中国农业大学理学院, 北京 100193
摘要
莠去津是一种广泛使用的除草剂, 我国是其原药的主要生产国家。 为加强工作场所莠去津暴露浓度的检测力度, 保障职业接触工人身体健康, 研究开发工作场所莠去津浓度的现场快速检测方法具有重要现实意义。 利用自行组装的便携式近红外光谱仪, 采集了实验室配置的浓度为10~1 000 mg·L-1的莠去津溶液样本光谱, 并比较了多元散射校正、 变量标准化、 一阶导数方法、 二阶导数方法及其组合等光谱预处理方法, 竞争自适应重加权采样变量选择法和遗传算法等变量选择方法, 偏最小二乘算法和支持向量机等回归方法对近红外光谱模型分析精度的影响。 研究发现一阶导数是最佳光谱预处理方法; 遗传算法优选的光谱变量表现优于竞争自适应重加权采样变量选择法; 支持向量机模型表现优于偏最小二乘模型。 基于遗传算法选择的16个光谱变量建立的支持向量机模型分析精度最高, 其定标决定系数、 验证决定系数、 定标均方差、 预测均方差和相对分析误差(成分浓度的标准偏差与预测均方差的比值)分别为1, 0.99, 17.54 mg·L-1, 25.42 mg·L-1和11.43, 有望应用于工作场所莠去津浓度的实际检测中。 该研究探讨了近红外光谱法检测工作场所莠去津浓度的可行性, 相关结果对于未来类似工作的开展具有重要参考价值。
Abstract
As a wildly used herbicide, Atrazine is mainly produced in China. In order to strengthen the routine detection of Atrazine exposure concentration and protect the health of occupational contact workers, it’s of great importance to develop on-site rapid detection method. A self-assembled near infrared spectrometer was used to record spectra of laboratory prepared atrazine solutions with concentration range from 10 to 1 000 mg·L-1. The influences of different pretreatment methods, such as multiplicative scatter correction, standard normal variate, first order derivative (D1), second order derivative and their combinations, different variable selection methods, such as competitive adaptive reweighted sampling (CARS) and genetic algorithm (GA), different regression methods, such as partial least square (PLS) and support vector regression(nu-SVR), on the model prediction accuracy were investigated. Results show that D1 is the best pretreatment method; GA obtain better results than CARS on selecting highly related spectral variables; nu-SVR model perform better than PLS model. The nu-SVR model constructed with 16 spectral variables selected by GA obtained the best results, whose coefficient of determination for calibration, the coefficient of determination for validation, root mean square error of calibration, root mean square error of validation (RMSEV) and residual validation deviation (defined as SD/RMSEV where SD denotes standard deviation) are 1, 0.99, 17.54 mg·L-1, 25.42 mg·L-1 and 11.43, respectively. These results indicate near infrared spectroscopy combined with chemometrics has great potential to quantify Atrazine concentration at workplace. This research explores the feasibility of quantification Atrazine at workplace with near infrared spectroscopy for the first time, which has great reference value for similar work in the future.

周兴藩, 宋相中, 付朝晖, 赵鹏, 许志珍, 唐仕川. 近红外光谱法快速测定工作场所莠去津浓度的研究[J]. 光谱学与光谱分析, 2017, 37(3): 755. ZHOU Xing-fan, SONG Xiang-zhong, FU Zhao-hui, ZHAO Peng, XU Zhi-zhen, TANG Shi-chuan. Rapid Detection of Atrazine at Workplace with Near-Infrared Spectroscopy[J]. Spectroscopy and Spectral Analysis, 2017, 37(3): 755.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!