摘要

根据现阶段光电瞄具的靶场测试需求,针对目前传统视差检测方法存在的无定量、大误差、低效率等缺点,提出了一种基于类正弦测微法的视差检测方法,该方法可实现光电瞄具视差的快速定量测试。采取传统摆头法的快速观测原理,利用类正弦测微法实现定量数据获取,构建出一台具有类正弦微动细分机构的改进型视差检测装置。选取了三类典型的光电瞄具样品,针对4种视差测试方法进行详细的测试效果比对实验。结果表明,基于类正弦测微法的视差检测方法及装置不仅能够保证0.01′的测试精度,而且能够满足光电瞄具靶场测试中效率高、精度高的需求,测试效果优于其他传统视差检测方法。

Abstract

According to the requirement of target range test of photoelectric sights at present stage, aiming at the defects of non-quantitative, large error and low efficiency of traditional parallax detection methods, a parallax detection method based on sine-like micrometric method is proposed. Quick and quantitative test of photoelectric sight parallax can be realized by the proposed method. Taking the fast-observing principle of the traditional pendulum method, sine-like micrometric method is used to realize the quantitative data acquisition, and an improved parallax detecting device with sine-like micromotion subdivision mechanism is constructed. Three kinds of typical optoelectronic sights samples are selected, and the test effect comparison experiments of four kinds of parallax test methods are conducted in detail. The results show that the parallax detection method and device based on sine-like micrometric method can not only ensure the testing accuracy of 0.01′,but also meet the requirement of high efficiency and high precision in the target range test of photoelectric sights, and the test result is superior to other traditional parallax detection methods.

Newport宣传-MKS新实验室计划
补充资料

中图分类号:TH745

DOI:10.3788/aos201838.0412003

所属栏目:仪器,测量与计量

基金项目:总装备部预研基金(614260610103)、吉林省重点科技攻关项目(201502040044GX)

收稿日期:2017-08-21

修改稿日期:2017-10-24

网络出版日期:--

作者单位    点击查看

牛津:长春理工大学光电工程学院, 吉林 长春 130114瞬态冲击技术重点实验室, 北京 102200
徐熙平:长春理工大学光电工程学院, 吉林 长春 130114
王舒:瞬态冲击技术重点实验室, 北京 102200
安志勇:长春理工大学光电工程学院, 吉林 长春 130114

联系人作者:徐熙平(xxp@cust.edu.cn)

备注:牛津(1988—),女,博士研究生,工程师,主要从事光电检测及仪器方面的研究。E-mail: niujin0615@163.com

【1】Liu Y, Kuang Z L. Electro-optical sights for light weapons[J]. Journal of Applied Optics, 2006, 27(3): 171-176.
刘宇, 邝自力. 轻武器光电瞄准具[J]. 应用光学, 2006, 27(3): 171-176.

【2】朱海军. 测量仪器视差产生原因及处置方法的研究[J]. 科技资讯, 2016, 14(28): 180.

【3】Cheng S C. Optical instrument calibration[M]. Beijing: Weapon Industry Press, 1992.
程守澄. 光学仪器检校[M]. 北京: 兵器工业出版社, 1992.

【4】Yang M Y, Kwon O D. Crater wear measurement using computer vision and automatic focusing[J]. Journal of Materials Processing Technology, 1996, 58(4): 362-367.

【5】Yu Q S, An Z Y, Yang R N, et al. Test of parallax parameters for optoelectronic sights in small arms[J]. Optics and Precision Engineering, 2010,18(8): 1732-1737.
于秋水, 安志勇, 杨瑞宁, 等. 轻武器光学瞄具的视差参数测试[J]. 光学 精密工程, 2010, 18(8): 1732-1737.

【6】Wang Q. Research on automatic parallax measurement of telescope system[D]. Tianjin: Tianjin University, 2014.
王铨. 望远系统视差自动测量技术研究[D]. 天津: 天津大学, 2014.

【7】Fu R, An Z Y, Zhu H B, et al. A new diopter and optical parallax testing system based on CCD[J]. Journal of Changchun University of Science and Technology (Natural Science Edition), 2010, 33(1): 22-25.
付饶, 安志勇, 朱海滨, 等. 一种基于CCD的视度视差测试新系统[J]. 长春理工大学学报(自然科学版), 2010, 33(1): 22-25.

【8】Cao W G,Zhu Y D,Duan J, et al. Measurement system based on diopter and optical parallax of CCD[J]. Infrared and Laser Engineering, 2007, 36(z1): 500-503.
曹维国, 朱运东, 段洁, 等. 基于CCD的视度和视差测试系统研究[J]. 红外与激光工程, 2007, 36(z1): 500-503.

【9】Zhang X M, Zhao H. A CCD image processing based automatic measurement system for diopter and optical parallax[J]. Electro-Optic and Control, 2012, 19(4): 72-75.
张晓明, 赵辉. 基于CCD图像处理的视度和视差自动检测系统[J]. 电光与控制, 2012, 19(4): 72-75.

【10】Wang S J, An Z Y, Wang J S, et al. The research of micromotion reading subdivision method[J]. Journal of Changchun University of Science and Technology (Natural Science Edition), 2010, 33(4): 58-61.
王偲姣, 安志勇, 王劲松, 等. 零位走动量测量的微动对零读数细分机构研究[J]. 长春理工大学学报(自然科学版), 2010, 33(4): 58-61.

【11】Xie W D, Yin H. Dynamic force calibration method for force transducers based on sine forceload[J]. Electrical and Mechanical Engineering, 2014, 31(4): 446-449.
谢伟东, 尹浩. 基于正弦力加载的力传感器动态标定技术研究[J]. 机电工程, 2014, 31(4): 446-449.

【12】Zhao H, Li C G, Chen Z T, et al. Design of collimating lens with uniform illumination for LED based on double freeform surface[J]. Acta Optica Sinica, 2017, 37(4): 0422001.
赵欢, 李长庚, 陈志涛, 等. 基于双自由曲面的LED均匀照明准直透镜设计[J]. 光学学报, 2017, 37(4): 0422001.

【13】Wang G M, Lao D B, Zhou W H. Optical system design and tolerance analysis of photoelectric self-collimation theodolite[J]. Laser & Optoelectronics Progress, 2017, 54(10): 102203.
王国名, 劳达宝, 周维虎. 光电自准直经纬仪光学系统设计与公差分析[J]. 激光与光电子学进展, 2017, 54(10): 102203.

【14】Liu C C, Cao T F, Ye H X, et al. Precise collimation technology and assembling optical modules in high power laser facility[J]. Acta Optica Sinica, 2015, 35(9): 0922001.
刘长春, 曹庭分, 叶海仙, 等. 大型精密光学系统准直误差分析方法及其应用[J]. 光学学报, 2015, 35(9): 0922001.

【15】Mao M, Wu Y N, Qin K H, et al. Fast parallax range estimation and its application[J]. Journal of Computer-Aided Design & Computer Graphics, 2015, 27(1): 120-127.
毛苗, 吴艳楠, 秦开怀, 等. 快速视差范围估计算法及其应用[J]. 计算机辅助设计与图形学学报, 2015, 27(1): 120-127.

【16】Sun X L. Research on the occlusion problem in visual measurement[D]. Harbin: Harbin Engineering University, 2013.
孙小玲. 视觉测量中遮挡问题的研究[D]. 哈尔滨: 哈尔滨工程大学, 2013.

【17】Shi B. Research on digital divergence parallax technology[D]. Changchun: Changchun University of Science and Technology, 2012.
史博. 数字式视度视差技术研究[D]. 长春: 长春理工大学, 2012.

【18】TianM, Liu J, Gao M. Parallax measurement of HUD based on computer vision[J]. Journal of Applied Optics, 2008, 29(5): 740-744.
田苗, 刘钧, 高明. 基于计算机视觉的平视显示器视差测量方法的研究[J]. 应用光学, 2008, 29(5): 740-744.

【19】Liu B Q, Zhou B. Automatic measurement of telescope system′s parallax using CCD[J]. Semiconductor Optoelectronics, 2005, 26(3): 253-255.
刘秉琦, 周斌. 利用CCD实现望远系统视差自动测试的研究[J]. 半导体光电, 2005, 26(3): 253-255.

【20】Li G, Zhou B, Dong W, et al. Measuring parallax of the telescope system with CCD device[J]. Optical Instruments, 2002, 24(2): 3-6.
李刚, 周冰, 董伟, 等. 一种视差的自动检测方法[J]. 光学仪器, 2002, 24(2): 3-6.

引用该论文

Niu Jin,Xu Xiping,Wang Shu,An Zhiyong. Fast Quantitative Parallax Test Based on Sine-Like Micrometric Method[J]. Acta Optica Sinica, 2018, 38(4): 0412003

牛津,徐熙平,王舒,安志勇. 基于类正弦测微法实现视差的快速定量测试[J]. 光学学报, 2018, 38(4): 0412003

您的浏览器不支持PDF插件,请使用最新的(Chrome/Fire Fox等)浏览器.或者您还可以点击此处下载该论文PDF