一种基于简化正交距离的近红外异常光谱判断方法

An Outlier Determination Method for Near-Infrared Spectroscopy Based on the Simplified Orthogonal Distance
作者单位
天津大学精密测试技术及仪器国家重点实验室, 天津 300072
摘要
及时发现并剔除异常光谱对于提高近红外光谱分析的可靠性具有重要意义。 首先介绍了基于正交距离的稳健主成分分析法判断异常光谱的原理, 分析了该方法的局限性, 在此基础上提出了一种基于简化正交距离的异常光谱判断方法, 即以高浓度样品的光谱直接估计第一稳健主成分, 再通过重复测量估计正交距离的统计参数来判断异常光谱。 最后, 采用上述两种方法对葡萄糖水溶液和2% Intralipid仿体溶液透射实验中受温度影响的异常光谱进行了判别。 结果表明, 基于正交距离的稳健主成分分析法, 当崩溃值设定为40%时, 葡萄糖水溶液和仿体溶液实验中受温度影响的异常光谱均能被正确识别; 当崩溃值设定为25%时, 对葡萄糖水溶液和仿体溶液实验中受温度影响的异常光谱漏判率分别为54.5%和72.7%。 而简化正交距离法可以准确识别出葡萄糖水溶液和仿体溶液实验中受温度干扰的异常光谱, 且具有无需预先设定崩溃值和测量持续时间较短等优点。 因此, 简化正交距离法在实际应用中相比基于正交距离的稳健主成分分析法有着显著的优势。
Abstract
Fast detecting and eliminating the outliers is of great significance to improve the reliability of the near-infrared(NIR) spectroscopy analysis. In this paper, the principle of outlier determination method based on orthogonal distance and robust principal component analysis was introduced firstly with the analysis of its limitations. Then an outlier determination method based on the simplified orthogonal distance was proposed, where the spectra of the samples with high concentration were employed to estimate the first robust principal component directly and the statistical parameters of the orthogonal distance were obtained with repeated measurements to detect outliers. Finally, the outliers caused by the temperature fluctuations in the NIR transmission spectra of glucose aqueous solutions and 2% Intralipid solutions, were determined by these two methods. Results showed that, for the orthogonal distance combined with robust principal component analysis method, all the outliers induced by temperature variations could be correctly determined under the collapse value of 40%, while the false negative rates for the glucose aqueous solutions and Intralipid solutions under the collapse value of 25% were 54.5% and 72.7%, respectively. Besides, all the outliers induced by temperature variations also could be recognized with the method based on the simplified orthogonal distance, which saves the need for collapse value and shortens the tine for measurement. Therefore, the outlier determination method based on the simplified orthogonal distance is more practical than the robust principal component analysis.

孟丹蕊, 傅博, 徐可欣, 刘蓉. 一种基于简化正交距离的近红外异常光谱判断方法[J]. 光谱学与光谱分析, 2018, 38(4): 1053. MENG Dan-rui, FU Bo, XU Ke-xin, LIU Rong. An Outlier Determination Method for Near-Infrared Spectroscopy Based on the Simplified Orthogonal Distance[J]. Spectroscopy and Spectral Analysis, 2018, 38(4): 1053.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!