为了满足电力系统中对SF6气体精确测量的需求,基于非分光红外差分检测原理,设计了一种便携式的SF6气体传感器。系统采用单光束双波长结构,对直射式和梯形反射式气室进行光学仿真,最终确定了气室类型,提高了系统的紧凑性和灵敏度。在电路方面设计了一种小信号放大滤波电路,有效地将有用信号从噪声中提取出来;传感器采用高精度高性能模数转换器将模拟电信号转换为数字信号送入单片机处理,大大提高了检测精度。实验结果表明,该传感器能够准确检测体积分数为0~2×10-3范围内的SF6气体,满量程精度可达4.2%。
Abstract
In order to satisfy the actual need of accurate measurement of SF6 gas concentration in the electrical system, a portable SF6 gas sensor was designed based on non-dispersive infrared (NDIR)differential detection principle, which adopted the single-beam and dual-wavelength optical structure. In order to improve the compactness and sensitivity of the system, the optical simulations of the straight and trapezoidal reflective gas chambers were carried out, and the gas chamber type was finally determined. As for designing hardware circuit, a small signal amplification filter circuit was designed to effectively extract the useful signal from the noise. The sensor uses the high precision and performance analog-to-digital converters to convert analog electrical signals into digital signals into single chip processor, which greatly improves the detection accuracy. The experimental results show the sensor can accurately measure the SF6 concentration in a range of 0~2×10-3, with the full range accuracy up to 4.2%.

沈婉, 常建华, 赵勇毅, 赵正杰, 裴昱. 便携式非分光红外SF6气体检测方法研究[J]. 应用光学, 2018, 39(4): 545. Shen Wan, Chang Jianhua, Zhao Yongyi, Zhao Zhengjie, Pei Yu. Research on method of portable NDIR SF6 gas detection[J]. Journal of Applied Optics, 2018, 39(4): 545.

本文已被 2 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!