光学 精密工程, 2018, 26 (8): 1967, 网络出版: 2018-10-02   

碳卫星CO2探测仪发射前的漫反射板定标

Preflight diffuser's calibration of carbon dioxide spectrometer of TanSat
作者单位
1 中国科学院 长春光学精密机械与物理研究所, 吉林 长春 130033
2 国家卫星气象中心, 北京 100081
摘要
为了提高CO2探测仪的在轨辐射定标精度, 建立了在轨辐射校正原理, 并对关键环节漫反射板的制备、BRDF定标和应用进行了系统的研究。根据CO2探测仪的工作原理与系统组成, 介绍了星上定标设备和在轨辐射定标策略, 确定了漫反射板的制备方法和优化工艺参数, 制定了以标准灯和标准探测器为传递链路的漫反射板BRDF的精确定标方法。对漫反射板基准BRDF、角度修正因子和半球反射率进行了测试, 对其实验室定标精度进行了分析, 并通过在轨初期的应用结果予以验证。发射前的定标结果表明, 漫反射板在760 nm、1 610 nm和2 060 nm 3个波段的定标精度均优于3%。在轨初期的测试结果表明CO2探测仪1 610 nm波段在轨绝对辐射定标精度优于5%。CO2探测仪漫反射板的定标结果满足仪器辐射定标对漫反射板定标的精度要求。
Abstract
In order to improve the on-orbit calibration accuracy of a CO2 spectrometer, the principle of on-orbit radiation correction was established, and key aspects such as the fabrication, BRDF calibration, and application of a diffuser were systematically studied. Based on the working principle and system composition of the CO2 spectrometer, the device and strategy for performing the on-orbit radiation calibration were introduced, and the fabrication method and optimization of the process parameters of the diffuser were established. Next, an accurate calibration method with lamps and detectors as transmission standards for the diffuser's BRDF are developed. The reference BRDF, angle correction factor, and hemispherical reflectivity of the diffuser were tested. In addition, the calibration accuracy in the laboratory was analyzed and subsequently verified by the application results obtained during the initial stage of the orbit. The results obtained before the launch show that the calibration accuracy of the diffuser was better than 3% for all three bands at 760 nm, 1 610 nm, and 2 060 nm. The initial test results on orbit indicate that the accuracy of the absolute radiation calibration of the CO2 spectrometer at 1 610 nm was better than 5%. These results can satisfy the accuracy requirements for the diffuser radiation calibration of the CO2 spectrometer.

王龙, 蔺超, 纪振华, 郑玉权, 毕研盟. 碳卫星CO2探测仪发射前的漫反射板定标[J]. 光学 精密工程, 2018, 26(8): 1967. WANG Long, LIN Chao, JI Zhen-hua, ZHENG Yu-quan, BI Yan-meng. Preflight diffuser's calibration of carbon dioxide spectrometer of TanSat[J]. Optics and Precision Engineering, 2018, 26(8): 1967.

本文已被 4 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!