强激光与粒子束, 2019, 31 (8): 083101, 网络出版: 2019-07-25  

一种220 GHz分布作用速调管的高频系统模拟

RF system of a 220 GHz extended interaction klystron
作者单位
1 中国科学院 电子学研究所, 北京 101400
2 中国科学院大学, 北京 100039
摘要
对一种基于双排矩形波导慢波结构(SDRWS)结构的3腔EIK进行了详细计算机模拟计算,通过对基于SDRWS结构的EIK用输入输出腔的S11的模拟计算及对分布作用速调管用中间腔的本征频率的模拟计算,初步确定了EIK用输入输出腔及中间腔的结构参数,进而对EIK进行了 PIC 互作用模拟计算,结果表明:该EIK的3 dB工作频带为219.5~220.5 GHz,3 dB带宽为1 GHz,最大功率为456 W,最大增益为40.06 dB。在此基础上,通过调整中间腔的波导头宽度以进行参差调谐,用PIC互作用模型模拟计算研究了中间腔谐振频率对EIK整体性能的影响。结果表明,EIK的3 dB工作频带主要由输入输出腔的通频带决定,而中间腔的谐振频率也具有重要影响。当中间腔的谐振频率分别处于输入输出腔的通频带的低频端或高频端时,可以使EIK的3 dB工作频带向低频端或高频端得到一定程度展宽;当中间腔的谐振频率高于输入输出腔的通频带的高频端时,EIK的增益在其3 dB工作频带内较为平坦,EIK的输出信号在其3 dB工作频带内比较稳定,频谱的纯净程度较好。参差调谐的最终结果表明,当中间腔的波导头宽度为0.747 mm时,EIK获得了接近最优的性能,3 dB工作频带为219.5~220.0 GHz,3 dB带宽扩展到1.2 GHz,最大功率为630 W,相应的最大电子效率为11.3%,最大增益为47 dB。
Abstract
An extended interaction klystron (EIK), which is composed of an input cavity and an output cavity both based on 8 periods of staggered double rectangular waveguide structure (SDRWS) and an intermediate cavity based on 6 periods of SDRWS, is calculated in detail on computer. After calculating reflection coefficient S11of the input cavity and output cavity and the eigenmodes of the intermediate cavity, the structural parameters of the input cavity and output cavity and the intermediate cavity are determined, then PIC simulation is done to predict the EIK’s performance, the results show that the EIK has an 1 GHz 3 dB bandwidth (219.5-220.5 GHz), a 456 W maximum power and a 40.06 dB maximum gain. Furthermore, stagger tuning by adjusting the structural parameter a of the intermediate cavity is performed to analyse how a affects the EIK’s performances, and the results show that the 3 dB band of the EIK mainly depends on the passband of the input cavity and output cavity, it also depends on the resonant frequency of the intermediate cavity in some cases. When the resonant frequency of the intermediate cavity is located at the lower or higher ends of the passband of the input cavity and output cavity, the 3 dB band of the EIK may be extended to certain extent. Particularly, when the resonant frequency of the intermediate cavity is located at or beyond the higher ends of the passband of the input cavity and output cavity, it is verified that the EIK has steady output signal featuring with pure spectrum and flat gains over the 3 dB band. The final results of the stagger tuning show that , when the structural parameter a of the intermediate cavity is 0.747 mm, the EIK reaches almost the optimum performances, with an 1.2 GHz 3 dB bandwidth (219.5-220.7 GHz), a 630 W maximum power companied with a 11.3% efficiency, and a 47 dB maximum gain.

王自成, 曲兆伟, 尚新文, 曹林林, 唐伯俊, 肖刘. 一种220 GHz分布作用速调管的高频系统模拟[J]. 强激光与粒子束, 2019, 31(8): 083101. Wang Zicheng, Qu Zhaowei, Shang Xinwen, Cao Linlin, Tang Bojun, Xiao Liu1. RF system of a 220 GHz extended interaction klystron[J]. High Power Laser and Particle Beams, 2019, 31(8): 083101.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!