红外与激光工程, 2019, 48 (8): 0814004, 网络出版: 2019-09-03   

基于超消色差1/4波片和AOTF的高光谱全偏振成像技术

Technology of hyperspectral full polarization imaging based on superachromatic 1/4 wave plate and acousto-optic tunable filter
张瑞 1,2,3解琨阳 1,2,3景宁 1,2,3王志斌 1,2,3陈媛媛 1,2,3李克武 1,2,3乔亚 1,3
作者单位
1 中北大学 山西省光电信息与仪器工程技术研究中心, 山西 太原 030051
2 中北大学 仪器科学与动态测试教育部重点实验室, 山西 太原 030051
3 中北大学 电子测试技术重点实验室, 山西 太原 030051
摘要
针对环境温度、电压、入射角等因素变化对基于声光可调谐滤波器(Acousto-optic tunable filter, AOTF)和液晶可变延迟器(Liquid crystal variable retarder, LCVR)的光谱偏振成像测量精度影响大, 且整个系统实现复杂等缺点; 考虑到超消色差波片对温度和波长依赖小, 结合AOTF高光谱成像的优点, 提出了基于超消色差1/4波片和AOTF的高光谱全偏振成像新方法。详细分析了该方法的工作原理, 并结合可购买到的最好超消色差1/4波片中相位延迟和快轴随波长的微小波动, 进而分析了该波动对偏振测量的影响, 并针对这些影响研究了修正策略。搭建了原理样机, 对450~950 nm波段进行了偏振测量, 修正后偏振度测量误差≤1%, 对偏振方向的测量偏差≤1.8°, 以633 nm为例, 对其全Stokes参量图像进行了具体原理及修正测量验证实验, 结果表明, 该新技术原理正确, 修正策略可行。该研究可为复杂条件下高精度、高光谱全偏振成像技术提供新的理论和实现方案。
Abstract
The measurement accuracy of spectropolarimetric imaging is severely affected by ambient temperature, voltage, and incident angle based on acousto-optic tunable filter(AOTF) and liquid crystal variable retarder(LCVR). The spectropolarimetric imaging system is more complex. However, the superachromatic wave plate has the advantage that the retardation varies very little with temperature and wavelength. According to it, a new method of full polarization hyperspectral imaging based on superachromatic wave plate and acousto-optic tunable filter was proposed. The working principle of the method was analyzed in detail. According to the slight fluctuation of retardation and the fast axis of the superachromatic 1/4 wave plate, the effect of this fluctuation on the polarization measurement was analyzed in detail. For these errors, a correction strategy was proposed. The specific principle of all the Stokes parameters images and the modified measurement verification experiment were performed for 633 nm waveband. The experiment result shows that the measurement error of the polarization degree of the system is less than 1% in the band of 450-950 nm, and the measurement deviation of the polarization orientation is less than 1.8°. The experimental results show that the new technology principle is correct and the correcting strategy is feasible. This research can provide new theory and implementation scheme for high-precision, high-resolution, full-polarization imaging technology under complex conditions.

张瑞, 解琨阳, 景宁, 王志斌, 陈媛媛, 李克武, 乔亚. 基于超消色差1/4波片和AOTF的高光谱全偏振成像技术[J]. 红外与激光工程, 2019, 48(8): 0814004. Zhang Rui, Xie Kunyang, Jing Ning, Wang Zhibin, Chen Yuanyuan, Li Kewu, Qiao Ya. Technology of hyperspectral full polarization imaging based on superachromatic 1/4 wave plate and acousto-optic tunable filter[J]. Infrared and Laser Engineering, 2019, 48(8): 0814004.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!