摘要
针对 GF-5全谱段光谱成像仪热红外谱段存在响应异常、辐射定标精度难以保障的问题,开展了地面辐射定标补充试验,发现热红外谱段响应对仪器内部温度、焦面温度变化敏感是导致异常现象的主要原因。进一步对 相机输出信号值随仪器内部温度、焦面温度变化规律进行了分析总结,提出了基于仪器温度、焦面温度修正的绝对辐射定标算法,成功应用于全谱段光谱成像仪热红外谱段的实验室绝对辐射定标,结果表明定标不确定性为 1.36%。
Abstract
Owing to the abnormal response of the thermal infrared bands of the visible infrared multi-spectral imager (VIMI) aboard GF-5 satellite it is challenging to guarantee the radiometric calibration accuracy; considering this fact, we conducted a supplementary test of ground radiometric calibration. We obtained that the response sensitivity of the thermal infrared bands to the change of instrument cavity temperature and the focal plane temperature was the main reason for this abnormal phenomenon. Furthermore, we analyzed and summarized the law of output signal changing with instrument cavity temperature and focal plane temperature. An absolute radiation calibration algorithm based on instrument temperature and focal plane temperature revise was proposed. It was successfully applied to laboratory absolute radiation calibration of thermal infrared bands of VIMI. The results show that the uncertainty of calibration is 1.36%.

王浩, 晋利兵, 李岩, 赵艳华. 基于温度修正的 GF-5全谱段光谱成像仪热红外谱段辐射定标[J]. 红外技术, 2020, 42(6): 547. WANG Hao, JIN Libing, LI Yan, ZHAO Yanhua. Radiation Calibration of Thermal Infrared Bands of GF-5 VIMI Based on Temperature Correction[J]. Infrared Technology, 2020, 42(6): 547.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!