应用光学, 2020, 41 (4): 754, 网络出版: 2020-08-20   

弹载脉冲光源有效光强空间分布测量装置研究 下载: 564次

Missile-borne measuring device of effective light intensity spatial distribution for pulsed light source
作者单位
1 北京理工大学 光电学院,北京 100081
2 西安应用光学研究所,国防科技工业光学一级计量站,陕西 西安 710065
摘要
研究了脉冲光源有效光强空间分布的Blondel-Rey法,采用复合梯形数值积分实现了瞬时光强的测量,并对高色温光源测量时的光谱失配校正进行了分析。构建了基于双反射镜同步测量原理的脉冲光源有效光强空间分布测量装置,详细分析了全空间分布式旋转平台、脉冲光强探测系统、光谱失配校正用高分辨率光谱仪等重点组成部件。采用高色温调制光源对测量装置进行了校准。最后,对该装置的测量不确定度进行了分析,其扩展不确定度可以达到3.0%。
Abstract
The Blondel-Rey method of effective light intensity spatial distribution for pulsed light source was studied. The measurement of instantaneous light intensity was realized by adopting the composite trapezium numerical integration, and the spectral mismatch correction of high color temperature light source measurement was analyzed. Based on the principle of double-reflector synchronous measurement, a measuring device of effective light intensity spatial distribution for pulsed light source was established. The key components such as whole space distributed rotating platform, pulsed light intensity detection system and high resolution spectrometer for spectral mismatch correction were analyzed in detail. And the measuring device was calibrated by using the high color temperature modulation light source. Finally, the measurement uncertainty of this measuring device was analyzed, and the expanded uncertainty could reach to 3.0%.

袁良, 邱丽荣, 康登魁, 李宏光, 刘瑞星, 卢飞, 俞兵, 姜昌录, 王生云. 弹载脉冲光源有效光强空间分布测量装置研究[J]. 应用光学, 2020, 41(4): 754. Liang YUAN, Lirong QIU, Dengkui KANG, Hongguang LI, Ruixing LIU, Fei LU, Bing YU, Changlu JIANG, Shengyun WANG. Missile-borne measuring device of effective light intensity spatial distribution for pulsed light source[J]. Journal of Applied Optics, 2020, 41(4): 754.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!