摘要

针对推扫型光学遥感器成像光学系统中线阵CCD探测器各像元响应不一致的现象,提出一种基于太阳漫反射板星上相对辐射定标方法。该方法以实验室积分球定标数据作为参考标准,对星上太阳漫反射板定标数据进行平场校正,消除了相机视场内杂散光及双向反射分布函数(BRDF)分布对相对定标结果带来的影响;进而得到各像元的相对定标系数,最后将相对定标系数应用于海洋、戈壁滩、云层三种不同地物目标场景。结果表明:三种地物场景的原始影像中存在的各种垂直条纹噪声可以得到有效消除;相对定标后各场景影像条纹系数均优于0.0045;基于太阳漫反射板相对定标方法可对线阵CCD探测器进行大动态范围内相对辐射校正,具有较高的时效性和定标精度,以满足星上相对辐射定标需求。

Abstract

In this study, we propose an on-board relative radiometric method based on a solar diffuser to correct the non-uniformity of the pixel response of the linear array CCD detector based on the imaging optical system of the push-room optical remote sensor. The proposed method uses laboratory integrating sphere calibration data as a reference standard to perform flat-field correction on the onboard calibration data, and the influences of the stray light in the field of view of the camera and the distribution of the bidirectional reflectance distribution function (BRDF) on the relative calibration results are eliminated; further, we obtain the relative calibration coefficients of each pixel, which can be applied to three different objects, i.e., the ocean, the Gobi desert, and the cloud. The results prove that the various vertical striping noises in the raw image can be effectively eliminated and that the image streaking metrics with respect to each scene is better than 0.0045 after relative calibration. Based on the solar diffuser, relative radiometric calibration for the linear array CCD detector in the large dynamic range can be realized, exhibiting considerable timeliness and calibration accuracy.

广告组1 - 空间光调制器+DMD
补充资料

中图分类号:P407.8

DOI:10.3788/AOS202040.0628002

所属栏目:遥感与传感器

基金项目:高分专项地面数据处理系统第二批研制项目、“十三五”航天预研基金;

收稿日期:2019-08-26

修改稿日期:2019-12-02

网络出版日期:2020-03-01

作者单位    点击查看

许和鱼:中国科学院安徽光学精密机械研究所通用光学与表征技术重点实验室, 安徽 合肥 230031中国科学技术大学, 安徽 合肥 230026
张黎明:中国科学院安徽光学精密机械研究所通用光学与表征技术重点实验室, 安徽 合肥 230031
李鑫:中国科学院安徽光学精密机械研究所通用光学与表征技术重点实验室, 安徽 合肥 230031
黄文薪:中国科学院安徽光学精密机械研究所通用光学与表征技术重点实验室, 安徽 合肥 230031
司孝龙:中国科学院安徽光学精密机械研究所通用光学与表征技术重点实验室, 安徽 合肥 230031
徐伟伟:中国科学院安徽光学精密机械研究所通用光学与表征技术重点实验室, 安徽 合肥 230031
葛曙乐:中国资源卫星应用中心, 北京 100094
赵艳华:北京空间机电研究所, 北京 100094
王浩:北京空间机电研究所, 北京 100094

联系人作者:许和鱼(1144152179@qq.com)

备注:高分专项地面数据处理系统第二批研制项目、“十三五”航天预研基金;

【1】Hartmut H H, Manning E M. Evaluation of the AIRS and CrIS relative radiometric calibration under cloudy conditions [J]. Proceedings of SPIE. 2014, 9218: 92180F.

【2】Wang M, Chen C C, Pan J, et al. A relative radiometric calibration method based on the histogram of side-slither data for high-resolution optical satellite imagery [J]. Remote Sensing. 2018, 10(3): 381.

【3】Li H C, Song H F. A relative radiometric correction method for linear array push-broom imagery [J]. Proceedings of SPIE. 2011, 8194: 81941L.

【4】Byun Y, Han D. Relative radiometric normalization of bitemporal very high-resolution satellite images for flood change detection [J]. Journal of Applied Remote Sensing. 2018, 12(2): 026021.

【5】Zheng L L, Jin G, Qu H S, et al. Non-uniformity correction for multi-channel TDI CCD imaging system in wide response range [J]. Acta Optica Sinica. 2017, 37(11): 1111001.
郑亮亮, 金光, 曲宏松, 等. 多通道宽响应域TDI CCD成像系统的非均匀性校正 [J]. 光学学报. 2017, 37(11): 1111001.

【6】Li X S, Liu H X, Sun J X, et al. Relative radiometric calibration for space camera with optical focal plane assembly [J]. Acta Optica Sinica. 2017, 37(8): 0828006.
李宪圣, 刘洪兴, 孙景旭, 等. 光学拼接焦平面空间相机的相对辐射定标 [J]. 光学学报. 2017, 37(8): 0828006.

【7】Krause K S. Relative radiometric characterization and performance of the QuickBird high-resolution commercial imaging satellite [J]. Proceedings of SPIE. 2004, 5542: 35-44.

【8】Krause K S. QuickBird relative radiometric performance and on-orbit long term trending [J]. Proceedings of SPIE. 2006, 6296: 62960P.

【9】Markham B, Barsi J, Kvaran G, et al. Landsat-8 Operational Land Imager Radiometric Calibration and Stability [J]. Remote Sensing. 2014, 6(12): 12275-12308.

【10】Zhang G, Li L T. A study on relative radiometric calibration without calibration field for YG-25 [J]. Acta Geodaetica et Cartographica Sinica. 2017, 46(8): 1009-1016.
张过, 李立涛. 遥感25号无场化相对辐射定标 [J]. 测绘学报. 2017, 46(8): 1009-1016.

【11】Morfitt R, Barsi J, Levy R, et al. Landsat-8 operational land imager (OLI) radiometric performance on-orbit [J]. Remote Sensing. 2015, 7(2): 2208-2237.

【12】Li H C, Man Y T. Relative radiometric calibration method based on linear CCD imaging the same region of non-uniform scene [J]. Proceedings of SPIE. 2014, 9299: 929906.

【13】Yan M, Wang Z Y, He S S, et al. A method of relative radiometric correction for linear push-broom CCD Image without calibration device onboard [J]. Proceedings of SPIE. 2011, 8203: 820303.

【14】Anderson C, Naughton D, Brun A, et al. Radiometric correction of Rapid Eye imagery using the on-orbit side-slither method . [C]∥Proceedings of SPIE. 2011, 8080: 818008.

【15】Pesta F, Bhatta S, Helder D, et al. Radiometric non-uniformity characterization correction of Landsat 8 OLI earth imagery-based techniques [J]. Remote Sensing. 2015, 7(1): 430-446.

【16】Gerace A, Schott J, Gartley M, et al. Ananalysis of the side slither on-orbit calibration technique using the DIRSIG model [J]. Remote Sensing. 2014, 6(11): 10523-10545.

【17】Pan Z Q, Gu X F, Liu G D, et al. Relativeradiometric correction of CBERS-01 CCD data based on detector histogram matching [J]. Geomatics and Information Science of Wuhan University. 2005, 30(10): 925-927.
潘志强, 顾行发, 刘国栋, 等. 基于探元直方图匹配的CBERS-01星CCD数据相对辐射校正方法 [J]. 武汉大学学报(信息科学版). 2005, 30(10): 925-927.

【18】Duan Y N, Zhang L F, Yan L, et al. Relative radiometric correction methods for remote sensing images and their applicability analysis [J]. Journal of Remote Sensing. 2014, 18(3): 597-617.
段依妮, 张立福, 晏磊, 等. 遥感影像相对辐射校正方法及适用性研究 [J]. 遥感学报. 2014, 18(3): 597-617.

【19】Xiong X, Che N, Xie Y, et al. Four-years on-orbit spectral characterization results for Aqua MODIS reflective solar bands [J]. Proceedings of SPIE. 2006, 6361: 63610S.

【20】Xiong X X, Angal A, Sun J Q, et al. On-orbit performance of MODIS solar diffuser stability monitor [J]. Journal of Applied Remote Sensing. 2014, 8(1): 083514.

【21】Olij C, Jos G, Henri G, et al. Spectralon diffuser calibration for MERIS [J]. Proceedings of SPIE. 1997, 3221: 63-74.

【22】Zhao Y H, Dai L Q, Bai S J, et al. Design andimplementation of full-spectrum spectral imager system [J]. Spacecraft Recovery & Remote Sensing. 2018, 39(3): 38-50.
赵艳华, 戴立群, 白绍竣, 等. 全谱段光谱成像仪系统设计及实现 [J]. 航天返回与遥感. 2018, 39(3): 38-50.

【23】Yang B Y, Zhang L M, Shen Z G, et al. Characteristic measurement of diffuser panel used for on-board calibration for satellite optical sensors [J]. Optics and Precision Engineering. 2009, 17(8): 1851-1858.
杨本永, 张黎明, 沈政国, 等. 光学传感器星上定标漫射板的特性测量 [J]. 光学精密工程. 2009, 17(8): 1851-1858.

【24】Ge Z, Chen J J, Li Y D, et al. Parameter test method for radiation damage of CCD [J]. Aerospace Shanghai. 2015, 32(2): 64-68.
葛钊, 陈佳杰, 李豫东, 等. CCD器件辐射损伤参数测试方法 [J]. 上海航天. 2015, 32(2): 64-68.

引用该论文

Xu Heyu,Zhang Liming,Li Xin,Huang Wenxin,Si Xiaolong,Xu Weiwei,Ge Shule,Zhao Yanhua,Wang Hao. A Relative Radiometric Calibration Method Based on Solar Diffuser Research for a Linear Array CCD Detector[J]. Acta Optica Sinica, 2020, 40(6): 0628002

许和鱼,张黎明,李鑫,黄文薪,司孝龙,徐伟伟,葛曙乐,赵艳华,王浩. 基于太阳漫反射板线阵CCD相对辐射定标方法研究[J]. 光学学报, 2020, 40(6): 0628002

被引情况

【1】黄文薪,张黎明,司孝龙,许和鱼,陈洪耀,李鑫,赵艳华. GF-5全谱段光谱成像仪星上定标组件在轨性能评价. 光学学报, 2020, 40(20): 2029001--1

您的浏览器不支持PDF插件,请使用最新的(Chrome/Fire Fox等)浏览器.或者您还可以点击此处下载该论文PDF