光子学报, 2006, 35 (4): 0587, 网络出版: 2010-06-03   

共聚焦成像系统中探测器对分辨率的影响

Influence of Detector on Resolution in Confocal Imaging System
作者单位
1 东华大学信息科学与技术学院,上海 200051
2 上海大学通信与信息工程学院,上海 200072
3 上海交通大学激光与光子生物研究所,上海 200030
引用该论文

葛华勇, 王保华, 任秋实. 共聚焦成像系统中探测器对分辨率的影响[J]. 光子学报, 2006, 35(4): 0587.

Ge Huayong, Wang Baohua, Ren Qiushi. Influence of Detector on Resolution in Confocal Imaging System[J]. ACTA PHOTONICA SINICA, 2006, 35(4): 0587.

参考文献

[1] Minsky M. Microscopy apparatus. USA Patent,30133467.1961

[2] Wilson T. Confocal microscopy. London: Academic Press,1990.1~78,123~156

[3] Gu M. Principles of three-dimensional imaging in confocal microscopes. Singapore: World Scientific Publishing Co. Pte. Ltd,1996.1~174

[4] Wilson T,Sheppard C J R. Imaging and super-resolution in the harmonic microscope. Opt Acta,1979,26 (8) :761~770

[5] Gu M,Sheppard C J R. Three-demensional coherent transfer functions for confocal imaging with unequal annular lenses. J of Modern Opt,1993,40(7): 1255~1272

[6] Yang C P,Tang Z L,Pei H J. Imaging analysis of two-photon confocal microscopy with different fluorescence wavelength. Acta Photonica Sinica,2004,33 (2) : 159~163

[7] Gao W R,Tao C K,ang X C. Relationship between the two dimensional resolution and signal-to-noise ratio of laser confocal microscopy. Acta Photonica Sinica,2002,31(6):730~735

[8] Qi Y J,Chi Z Y,Chen W J,et al. The further studying of PSF in confocal scanning microscopy system. Acta Photonica Sinica,2002,31(8):1029~1031

[9] Fu L,Luo Q M,Lu Q,et al. Effect of sattering and absorption properties of bidogical tissue on two-photon excitation and confocal imaging depth. Acta Photonica Sinica,2001,30(3) : 262~266

[10] Wilson T,Carlini A R. Size of the detector in confocal imaging system. Opt Lett,1987,12(4): 227~229

[11] Gu M,Sheppard C J R. Three-dimensional partiallycoherent image formation in confocal microscopes with a finite-sized detector. J of Modern Opt,1994,41 (9)1701~1715

[12] Drazic V. Three-dimensional transfer function analysis of a confocal fluorescence microscope with a finite-sized source and detector. J of Modern Opt,1993,40(5):879~887

[13] Wilson T,Sheppard C R J. Theory and practice of scanning optical microscopy. London: Academic Press,1984.42~78

[14] Sheppard C J R,Wilson T. Image formation in scanning microscopes with partially coherent source and detector. Optica Acta,1978,25(4) :315~325

葛华勇, 王保华, 任秋实. 共聚焦成像系统中探测器对分辨率的影响[J]. 光子学报, 2006, 35(4): 0587. Ge Huayong, Wang Baohua, Ren Qiushi. Influence of Detector on Resolution in Confocal Imaging System[J]. ACTA PHOTONICA SINICA, 2006, 35(4): 0587.

本文已被 5 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!