Chinese Optics Letters, 2012, 10 (4): 042802, Published Online: Jan. 5, 2012   

Study on long distance transmission technique of weak photocurrent signal in laser gas sensor Download: 585次

Author Affiliations
Abstract
The continuous monitoring of H2S gas concentration is a common problem in natural gas desulfurization process technology. Tunable diode laser absorption spectroscopy (TDLAS) is a preferred technology for continuous monitoring of gas in industrial sites, because of its high selectivity, high sensitivity, and fast response. We discuss the technical solutions of on-line monitoring of H2S in natural gas desulfurization process technology based on TDLAS, and study the security design of monitoring system in inflammable and explosive areas. We also design a weak photocurrent signal converting circuit and perform experiments on transmission characteristics of different distances. The signal-to-noise ratio (SNR) of laser absorption spectrum does not decrease after the 1 500-m transmission. The detection limit is 300 ppb. The system can be operated stably and reliably, and satisfies the need for continuous monitoring of the H2S in natural gas desulfurization process.

Liming Wang, Yujun Zhang, Hongbin Li, Yi Zhou, Kun You, Ying He, Wenqing Liu. Study on long distance transmission technique of weak photocurrent signal in laser gas sensor[J]. Chinese Optics Letters, 2012, 10(4): 042802.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!