强激光与粒子束, 2005, 17 (7): 1000, 网络出版: 2006-04-28  

用吸收光谱法测量COIL的水汽含量

Measurement of water vapor content in COIL by absorption spectroscopy at 1 392 nm
作者单位
1 中国科学院大连化学物理研究所,辽宁,大连116023
2 海军大连舰艇学院,辽宁,大连116018
3 中国科学院大连化学物理研究所,辽宁大连116023
摘要
分析了利用吸收光谱法测量氧碘化学激光器的水汽含量的原理,在氯气流量为0.1 mol/s的N2-COIL上进行了测试实验.实验结果显示,在常规工作条件下,由于BHP温度变化所引起的水汽百分含量变化仅为0.1%,可以忽略;水汽含量随稀释气体流量增大而增加,气体流速是引起水汽含量变化的主要原因,实验中应把氯气和氧气的比例控制在4∶1之内.
Abstract
We measured the water vapor fraction in COIL by absorption spectroscopy. Measurements showed that the change of water vapor fraction due to the basic hydrogen peroxide(BHP)temperature could be ignored during normal operation. The water content rises with the increasing of buffer gas flow rate. It is indicated that the gas flow velocity is the main reason that affects on the water vapor fraction in COIL.

赵伟力, 王增强, 房本杰, 李庆伟, 金玉奇, 桑凤亭. 用吸收光谱法测量COIL的水汽含量[J]. 强激光与粒子束, 2005, 17(7): 1000. ZHAO Wei-li, WANG Zeng-qiang, FANG Ben-jie, LI Qing-wei, JIN Yu-qi, SANG Feng-ting. Measurement of water vapor content in COIL by absorption spectroscopy at 1 392 nm[J]. High Power Laser and Particle Beams, 2005, 17(7): 1000.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!