强激光与粒子束, 2003, 15 (7): 639, 网络出版: 2006-04-28
DF/HF化学激光器HYLTE喷管的副喷管质量流量系数
Mass flowrate coefficient in relation to secondary flow of HYLTE nozzle in DF/HF chemical lasers
DF/HF化学激光器 HYLTE喷管 质量流量系数 DF/HF chemical laser Hypersonic low temperature nozzle Mass flowrate coefficient
摘要
对DF/HF化学激光器HYLTE喷管的副喷管质量流量进行了数值和理论计算,得出入口滞止压力在0.01~0.4MPa之间、喉道半高度在0.1~0.9mm之间的喷管的氘气,氢气和氦气质量流量系数,总结出质量流量系数随入口滞止压力和喉道高度的变化规律,并给出拟合公式,为副喷管的设计提供依据.
Abstract
The secondary mass flowrate of the HYLTE nozzle in DF/HF chemical lasers was numerically and theoretically calculated, the mass flowrate coefficients of D2,H2 and He with 0.01~0.4MPa stagnation pressure and 0.1~0.9mm height of the half throat are obtained. The changerules of mass flowrate coefficient with stagnation pressure and half throat's height were got, the functions deduced from these rules were of satisfactory preciseion. As a result, some suggestions are presented on the design and maintenance of secondary nozzle.
施建华, 袁圣付, 华卫红, 姜宗福, 王红岩. DF/HF化学激光器HYLTE喷管的副喷管质量流量系数[J]. 强激光与粒子束, 2003, 15(7): 639. 施建华, 袁圣付, 华卫红, 姜宗福, 王红岩. Mass flowrate coefficient in relation to secondary flow of HYLTE nozzle in DF/HF chemical lasers[J]. High Power Laser and Particle Beams, 2003, 15(7): 639.