Matter and Radiation at Extremes, 2020, 5 (4): 044401, Published Online: Nov. 25, 2020  

Focal-shape effects on the efficiency of the tunnel-ionization probe for extreme laser intensities

Author Affiliations
1 Institute of Physics of the ASCR, ELI-Beamlines Project, Na Slovance 2, 182 21 Prague, Czech Republic
2 ICFO—Institut de Ciencies Fotoniques, Barcelona Institute of Science and Technology, Av. Carl Friedrich Gauss 3, 08860 Castelldefels (Barcelona), Spain
3 National Research Nuclear University MEPhI, Kashirskoe Ave. 31, 115409 Moscow, Russia
4 Prokhorov General Physics Institute of the Russian Academy of Sciences, Vavilov Str. 38, 119991 Moscow, Russia
Abstract
We examine the effect of laser focusing on the effectiveness of a recently discussed scheme [M. F. Ciappina et al., Phys. Rev. A 99, 043405 (2019) and M. F. Ciappina and S. V. Popruzhenko, Laser Phys. Lett. 17, 025301 (2020)] for in situ determination of ultrahigh intensities of electromagnetic radiation delivered by multi-petawatt laser facilities. Using two model intensity distributions in the focus of a laser beam, we show how the resulting yields of highly charged ions generated in the process of multiple sequential tunneling of electrons from atoms depend on the shapes of these distributions. Our findings lead to the conclusion that an accurate extraction of the peak laser intensity can be made either in the near-threshold regime, when the production of the highest charge state happens only in a small part of the laser focus close to the point where the intensity is maximal or through the determination of the points where the ion yields of close charges become equal. We show that for realistic parameters of the gas target, the number of ions generated in the central part of the focus in the threshold regime should be sufficient for a reliable measurement with highly sensitive time-of-flight detectors. Although the positions of the intersection points generally depend on the focal shape, they can be used to localize the peak intensity value in certain intervals. Finally, the slope of the intensity-dependent ion yields is shown to be robust with respect to both the focal spot size and the spatial distribution of the laser intensity in the focus. When these slopes can be measured, they will provide the most accurate determination of the peak intensity value within the considered tunnel ionization scheme. In addition to this analysis, we discuss the method in comparison with other recently proposed approaches for direct measurement of extreme laser intensities.

M. F. Ciappina, E. E. Peganov, S. V. Popruzhenko. Focal-shape effects on the efficiency of the tunnel-ionization probe for extreme laser intensities[J]. Matter and Radiation at Extremes, 2020, 5(4): 044401.

引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!