光学 精密工程, 2018, 26 (9): 2304, 网络出版: 2018-12-16   

用于aPTT测量的Parylene-C增强型石英晶体微天平耗散检测系统

Parylene-C enhanced quartz crystal microbalance based dissipation detecting system for aPTT measurement
作者单位
1 上海大学 通信与信息工程学院, 上海 200444
2 中国科学院 苏州生物医学工程技术研究所, 江苏 苏州 215163
3 苏州大学 电子信息学院, 江苏 苏州 215006
引用该论文

丰斌, 姚佳, 张威, 孔慧, 魏巍, 周连群. 用于aPTT测量的Parylene-C增强型石英晶体微天平耗散检测系统[J]. 光学 精密工程, 2018, 26(9): 2304.

FENG Bin, YAO Jia, ZHANG Wei, KONG Hui, WEI Wei, ZHOU Lian-qun. Parylene-C enhanced quartz crystal microbalance based dissipation detecting system for aPTT measurement[J]. Optics and Precision Engineering, 2018, 26(9): 2304.

参考文献

[1] CARDENAS J, REIN S C, CHURCH F. Overview of Blood Coagulation and the Pathophysiology of Blood Coagulation Disorders [M]. Amsterdam: Elsevier Press, 2016.

[2] HARRIS L F, CASTRO L V, KILLARD A J. Coagulation monitoring devices: Past, present, and future at the point of care [J]. Trends in Analytical Chemistry, 2013, 50: 85-95.

[3] HARRIS L, LAKSHMANAN R S, EFREMOV V, et al.. Point of care (POC) blood coagulation monitoring technologies[M]. Medical Biosensors for Point of Care (POC) Applications. 2017.

[4] HUSSAIN M, WENDEL H P, SCHMIDT K, et al.. QCM-D surpassing clinical standard for the dose administration of new oral anticoagulant in the patient of coagulation disorders [J]. Biosensors & Bioelectronics, 2017, 104: 15.

[5] WITT V, PICHLER H, BEIGLBOECK E, et al.. Changes in hemostasis caused by different replacement fluids and outcome in therapeutic plasma exchange in pediatric patients in a retrospective single center study [J]. Transfusion & Apheresis Science Official Journal of the World Apheresis Association Official Journal of the European Society for Haemapheresis, 2017, 56(1): 59.

[6] HUSSAIN M. QCM-D for Haemostasis Assays: Current Status and Future: A Review [J]. UK Journal of Pharmaceutical and Biosciences, 2016, 4(1): 121-132.

[7] LEI K F, CHEN K H, TSUI P H, et al.. Real-time electrical impedimetric monitoring of blood coagulation process under temperature and hematocrit variations conducted in a microfluidic chip [J]. Plos One, 2013, 8(10): e76243.

[8] CHEN D, SONG S, MA J, et al.. Micro-electromechanical film bulk acoustic sensor for plasma and whole blood coagulation monitoring [J]. Biosensors & Bioelectronics, 2016, 91: 465.

[9] YANG C L, HUANG S J, CHOU C W, et al.. Design and evaluation of a portable optical-based biosensor for testing whole blood prothrombin time [J]. Talanta, 2013, 116(22): 704-711.

[10] 薛严冰, 李亚, 于婧怡. 基于PANI/SnO2符合材料的QCM水果气体传感器[J]. 光学 精密工程, 2015, 24(10): 0511-0519.

    XUE Y B, LI Y, YU J Y. QCM fruit gas sensor based on PANI/SnO2 composite materials [J]. Opt. Precision Eng., 2015, 24(10): 0511-0519. (in Chinese)

[11] 张冬至. 静电诱导自组装碳纳米管薄膜的结构表征与电学性能 [J]. 光学 精密工程, 2014, 22(6): 1562-1570.

    ZHANG D ZH. Structure characterization and electric properties of electrostatic-induced self-assembly carbon nanotube films [J]. Opt. Precision Eng., 2014, 22(6): 1562-1570. (in Chinese)

[12] HUSSAIN M, NORTHOFF H, GEHRING F K. QCM-D providing new horizon in the domain of sensitivity range and information for haemostasis of human plasma [J]. Biosensors and Bioelectronics, 2015, 66: 579-584.

[13] JIN J, JIANG W, YIN J, et al.. Stagnaro P. Plasma Proteins Adsorption Mechanism on Polyethylene-Grafted Poly(ethylene glycol) Surface by Quartz Crystal Microbalance with Dissipation [J]. Langmuir., 2013, 29(22): 6624-6633.

[14] EFREMOV V, KILLARD A J, BYRNE B, et al.. The modelling of blood coagulation using the quartz crystal microbalance [J]. Journal of Biomechanics, 2013, 46(3): 437.

[15] MULLER L, SINN S, DRECHSEL H, et al.. Investigation of prothrombin time in human whole-blood samples with a quartz crystal biosensor [J]. Analytical Chemistry, 2010, 82(2): 658.

[16] 李敬, 潘海曦, 郭振, 等. Parylene增强型声表面波传感器及其温度响应 [J]. 光学 精密工程, 2017, 25(12): 3048-3055.

    LI J, PAN H X, GUO ZH, et al.. Parylene-enhanced SAW sensor and its temperature response [J]. Opt. Precision Eng., 2017, 25(12): 3048-3055. (in Chinese)

[17] YANG Y, WEI Z, ZHEN G, et al.. Stability Enhanced, Repeatability Improved Parylene-C Passivated on QCM Sensor for aPTT Measurement [J]. Biosensors and Bioelectronics, 2017, 98: 41-46.

[18] LAKSHMANAN R S, EFREMOV V, CULLEN S M, et al.. Measurement of the evolution of rigid and viscoelastic mass contributions from fibrin network formation during plasma coagulation using quartz crystal microbalance [J]. Sensors and Actuators B: Chemical, 2014, 192(3): 23-28.

[19] 黄佳. 高频小型石英晶体微天平的研究[D]. 东南大学, 2015.

    HUANG J.Study on miniaturized high-frequency quzrtz crystal microbalance [D]. Southeast University, 2015. (in Chinese)

[20] SINAURIDZE E I, VUIMO T A, TARANDOVSKIY I D, et al.. Thrombodynamics, a new global coagulation test: Measurement of heparin efficiency [J]. Talanta, 2017, 180: 282-291.

丰斌, 姚佳, 张威, 孔慧, 魏巍, 周连群. 用于aPTT测量的Parylene-C增强型石英晶体微天平耗散检测系统[J]. 光学 精密工程, 2018, 26(9): 2304. FENG Bin, YAO Jia, ZHANG Wei, KONG Hui, WEI Wei, ZHOU Lian-qun. Parylene-C enhanced quartz crystal microbalance based dissipation detecting system for aPTT measurement[J]. Optics and Precision Engineering, 2018, 26(9): 2304.

本文已被 2 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!